FieldServer FS-8704-14 instruction manual Table of Contents

Page 2

FS-8704-14 EtherNet/IP ManualTable of Contents

TABLE OF CONTENTS

1

EtherNet/IP Description

4

 

1.1

ODVA Status.

..................................................................................................................................................

4

2 Driver Scope of Supply

4

 

2.1

Supplied by FieldServer Technologies for this driver

4

3

Hardware Connections

5

4 Configuring the FieldServer as an EtherNet/IP Client

6

 

4.1

Data Arrays/Descriptors

6

 

4.2

Client Side Connection Descriptions

7

 

4.3

Client Side Node Descriptors

7

 

4.4

Client Side Map Descriptors

8

 

4.4.1

FieldServer Related Map Descriptor Parameters

8

 

4.4.2

Driver Related Map Descriptor Parameters – Unconnected Messages

8

 

4.4.3

Driver Related Map Descriptor Parameters – Data Table Read/Write

9

 

4.4.4

Driver Related Map Descriptor Parameters – PCCC

10

 

4.4.5

Timing Parameters

10

 

4.4.6

Map Descriptor Example 1: Unconnected Messages

11

 

4.4.7

Map Descriptor Example 2: Data Table Messages

11

 

4.4.8

Map Descriptor Example 3: PCCC Messages

11

5 Configuring the FieldServer as an EtherNet/IP Server

12

 

5.1

Server Side Connection Descriptors

12

 

5.2

Server Side Node Descriptors3

13

 

5.3

Server Side Map Descriptors

13

 

5.3.1

FieldServer Specific Map Descriptor Parameters

13

 

5.3.2

Server Specific Map Descriptor Parameters – Unconnected Messages

14

 

5.3.3

Server Specific Map Descriptor Parameters – Data Table Read/Write

14

 

5.3.4

Driver Related Map Descriptor Parameters – PCCC

15

 

5.3.5

Map Descriptor Example 1: Unconnected Messages

16

 

5.3.6

Map Descriptor Example 2: Data Table Messages

16

 

5.3.7

Map Descriptor Example 3: PCCC Messages

16

Appendix A. Advanced Topics

17

 

Appendix A.1. General Notes

17

 

Appendix A.2. FieldServer as an Adapter and Scanner

17

 

Appendix A.3. Common Paths

17

 

Appendix A.4. Setting the Data Type for stored data

17

 

Appendix A.5. Configuring a PLC to read and write data to and from FieldServer

17

 

Appendix A.5.1. FieldServer Configuration File

18

 

Appendix A.5.2.

The PLC Program

19

 

Appendix A.6. Configuring a FieldServer to read and write Data to and from a PLC

21

 

Appendix A.6.1. FieldServer Configuration File

22

 

Appendix A.6.2.

The PLC Program

23

 

Appendix A.7. Read/write structures and value of EIP_Structure_Handle :

23

 

Appendix A.8. Classes and Attributes Supported

25

 

Appendix A.9. Error Codes

27

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

Image 2
Contents Driver Manual FS-8704-14 EtherNet/IP Table of Contents Appendix C. Error Messages Odva Status Supplied by FieldServer Technologies for this driverHardware Connections Configuring the Fieldserver AS AN ETHERNET/IP Client Data Arrays/DescriptorsClient Side Connection Descriptions Client Side Node Descriptors3There can be 200 Floats FS-8704-14 EtherNet/IP ManualPage 9 Driver Related Map Descriptor Parameters Pccc Timing ParametersMap Descriptor Example 3 Pccc Messages Map Descriptor Example 1 Unconnected MessagesMap Descriptor Example 2 Data Table Messages Configuring the Fieldserver AS AN ETHERNET/IP Server Server Side Connection DescriptorsServer Side Node Descriptors3 FS-8704-14 EtherNet/IP ManualPage 14 FS-8704-14 EtherNet/IP ManualPage 15 SMDPRO01 Appendix A.2. FieldServer as an Adapter and Scanner Appendix A.4. Setting the Data Type for stored dataAppendix A.1. General Notes Appendix A.3. Common PathsEipservice Eiptagname Step Read Message Block FS-8704-14 EtherNet/IP Manual Appendix A.6.1 FieldServer Configuration File FieldServer as a Client SSSSINT3 Attributes Supported Services Supported Appendix A.8. Classes and Attributes SupportedAttributes Supported Services Supported Appendix A.9. Error Codes Attempt to change number of array dimensions Appendix B.1. Firmware Update Downloading Appendix B.3. FieldServer not recognised by RSlinxAppendix C. Error Messages

FS-8704-14 specifications

The FieldServer FS-8704-14 is a state-of-the-art communication gateway designed for seamless integration of various devices and protocols within building automation and industrial control systems. This versatile device is equipped with multiple features that cater to the needs of system integrators and end-users alike, making it a popular choice in modern facilities management.

One of the standout features of the FS-8704-14 is its support for a wide variety of communication protocols. This model can bridge the gap between different systems by facilitating communication among protocols such as Modbus RTU, Modbus TCP, BACnet IP, BACnet MSTP, and LonWorks, to name a few. This multi-protocol capability ensures that legacy systems can communicate with newer technologies, providing a future-proof solution for businesses looking to upgrade their infrastructure.

The FS-8704-14 is equipped with 14 configurable input/output points, offering a flexible approach to system design. Users can customize how these points are used, enabling the device to adapt to various application requirements. This configurability extends to both digital and analog inputs, allowing for monitoring and control of a range of sensors and actuators within a building or industrial environment.

In terms of connectivity, the device supports Ethernet, allowing for easy integration into existing networks. The FS-8704-14's robust web interface simplifies configuration and monitoring, making it accessible to users with different levels of technical expertise. This intuitive interface ensures that users can effectively manage the gateway without extensive training.

Another notable characteristic of the FS-8704-14 is its built-in data logging capabilities. This feature enables the collection and analysis of operational data, promoting better decision-making and operational efficiency. Users can access historical data, which aids in predictive maintenance and optimization of system performance.

In summary, the FieldServer FS-8704-14 is a powerful communication gateway that demonstrates exceptional flexibility and compatibility with various automation protocols. Its configurable I/O points, robust web interface, and data logging capabilities make it an essential tool for integrating disparate systems in both building automation and industrial applications. With its comprehensive feature set, the FS-8704-14 helps organizations achieve greater efficiency, reliability, and scalability in their operations.