FieldServer FS-8704-14 instruction manual Read Message Block

Page 20

FS-8704-14 EtherNet/IP Manual

Page 20 of 30

 

 

Step 4

Configure the Properties for the two Message Blocks by clicking on the “…” button:

Read Message Block:

Remote FieldServer Tag Configured in the FieldServer (see example above)

Number of points transferred from FieldServer to PLC regardless of Tag and Array Sizes

Local PLC Tag configured in the PLC Tag List (see example above)

Write Message Block:

Local PLC Tag configured in the PLC Tag List (see example above)

Number of points transferred from PLC to FieldServer regardless of Tag and Array Sizes

Remote FieldServer Tag configured in the FieldServer (see example above)

Communication Tab for both Message Blocks:

The Tag Tab requires no configuration.

EIP_Card is the name of the Ethernet ENBT Card in the ControlLogix Rack.

“2” refers to the port number on the ENBT Card. 192.168.1.75 is the IP Address of the FieldServer.

Step 5

Download the program and set the PLC to Run Mode.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

Image 20
Contents Driver Manual FS-8704-14 EtherNet/IP Table of Contents Appendix C. Error Messages Odva Status Supplied by FieldServer Technologies for this driverHardware Connections Configuring the Fieldserver AS AN ETHERNET/IP Client Data Arrays/DescriptorsClient Side Connection Descriptions Client Side Node Descriptors3There can be 200 Floats FS-8704-14 EtherNet/IP ManualPage 9 Driver Related Map Descriptor Parameters Pccc Timing ParametersMap Descriptor Example 3 Pccc Messages Map Descriptor Example 1 Unconnected MessagesMap Descriptor Example 2 Data Table Messages Configuring the Fieldserver AS AN ETHERNET/IP Server Server Side Connection DescriptorsServer Side Node Descriptors3 FS-8704-14 EtherNet/IP ManualPage 14 FS-8704-14 EtherNet/IP ManualPage 15 SMDPRO01 Appendix A.4. Setting the Data Type for stored data Appendix A.1. General NotesAppendix A.2. FieldServer as an Adapter and Scanner Appendix A.3. Common PathsEipservice Eiptagname Step Read Message Block FS-8704-14 EtherNet/IP Manual Appendix A.6.1 FieldServer Configuration File FieldServer as a Client SSSSINT3 Attributes Supported Services Supported Appendix A.8. Classes and Attributes SupportedAttributes Supported Services Supported Appendix A.9. Error Codes Attempt to change number of array dimensions Appendix B.1. Firmware Update Downloading Appendix B.3. FieldServer not recognised by RSlinxAppendix C. Error Messages

FS-8704-14 specifications

The FieldServer FS-8704-14 is a state-of-the-art communication gateway designed for seamless integration of various devices and protocols within building automation and industrial control systems. This versatile device is equipped with multiple features that cater to the needs of system integrators and end-users alike, making it a popular choice in modern facilities management.

One of the standout features of the FS-8704-14 is its support for a wide variety of communication protocols. This model can bridge the gap between different systems by facilitating communication among protocols such as Modbus RTU, Modbus TCP, BACnet IP, BACnet MSTP, and LonWorks, to name a few. This multi-protocol capability ensures that legacy systems can communicate with newer technologies, providing a future-proof solution for businesses looking to upgrade their infrastructure.

The FS-8704-14 is equipped with 14 configurable input/output points, offering a flexible approach to system design. Users can customize how these points are used, enabling the device to adapt to various application requirements. This configurability extends to both digital and analog inputs, allowing for monitoring and control of a range of sensors and actuators within a building or industrial environment.

In terms of connectivity, the device supports Ethernet, allowing for easy integration into existing networks. The FS-8704-14's robust web interface simplifies configuration and monitoring, making it accessible to users with different levels of technical expertise. This intuitive interface ensures that users can effectively manage the gateway without extensive training.

Another notable characteristic of the FS-8704-14 is its built-in data logging capabilities. This feature enables the collection and analysis of operational data, promoting better decision-making and operational efficiency. Users can access historical data, which aids in predictive maintenance and optimization of system performance.

In summary, the FieldServer FS-8704-14 is a powerful communication gateway that demonstrates exceptional flexibility and compatibility with various automation protocols. Its configurable I/O points, robust web interface, and data logging capabilities make it an essential tool for integrating disparate systems in both building automation and industrial applications. With its comprehensive feature set, the FS-8704-14 helps organizations achieve greater efficiency, reliability, and scalability in their operations.