FieldServer FS-8700-59 instruction manual Data Arrays, Column Title Function Legal Values

Page 5

FS-8700-59 Canatal Sachnet

Driver Manual

4.Configuring the FieldServer as a Canatal Satchnet Protocol Driver Client

For a detailed discussion on FieldServer configuration, please refer to the Configuration Manual for the FieldServer. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” files on the driver diskette).

This section documents and describes the parameters necessary for configuring the FieldServer as a master, configured to communicate with a Canatal Satchnet Protocol Driver Server ( a passive Canatal device).

The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for Canatal Satchnet Protocol Driver communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays” section, the destination device addresses need to be declared in the “Client Side Nodes” section, and the data required from the servers needs to be mapped in the “Client Side Map Descriptors” section. Details on how to do this can be found below.

 

Note that in the tables,

* indicates an optional parameter, with the bold legal value being the

 

default.

 

 

4.1 Data Arrays

 

 

 

 

 

 

 

Section Title

 

 

 

Data_Arrays

 

 

 

Column Title

Function

Legal Values

 

Data_Array_Name

Provide name for Data Array

Up to 15 alphanumeric

 

 

 

characters

 

Data_Format

Provide data format. Each data array can only

FLOAT, BIT, UInt16, SInt16,

 

 

take on one format.

Packed_Bit, Byte,

 

 

 

Packed_Byte, Swapped_Byte

 

Data_Array_Length

Number of Data Objects. Must be larger than

1-10,000

 

 

the data storage area required for the data

 

 

 

being placed in this array.

 

 

 

 

 

Example

//Data Arrays

Data_Arrays

Data_Array_Name, Data_Format, Data_Array_Length

DA_AI_01,

UInt16,

200

DA_AO_01,

UInt16,

200

DA_DI_01,

Bit,

200

DA_DO_01,

Bit,

200

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042

Visit our website: www.fieldserver.com E-mail: support@fieldserver.com

Page 3

Image 5
Contents FS-8700-59 Canatal Satchnet Driver Table of Contents RS-485 connection adapter Driver Manual Supplied by FieldServer Technologies for this driverProvided by user Canatal Device UTP or similar cable with RJ11 adapterHardware Connections Interconnecting Cable CharacteristicsColumn Title Function Legal Values Data ArraysClient Side Nodes Client Side ConnectionsFieldServer Specific Map Descriptor Parameters Client Side Map DescriptorsDriver Specific Map Descriptor Parameters Timing ParametersDEV23COOL Anaout Map Descriptor ExampleTBL05DATA ,0 Rdbc , DEV11 Data Arrays Server Side Nodes Server Side ConnectionsServer Side Map Descriptors DEV11TBL5 Canatal Device Data Tables Driver NotesSeries Data Format Max Read Description Troubleshooting Error. Poll%d/Response%d Tables Not Equal Error. Poll%d/Response%d Stns Not EqualThat the device is not functioning correctly CANA#15

FS-8700-59 specifications

The FieldServer FS-8700-59 is a versatile communication gateway designed to facilitate seamless integration between various building automation systems and electronic devices. This robust device is part of the FieldServer family, known for its commitment to enabling interoperability in heterogeneous environments. The FS-8700-59 caters primarily to system integrators, facility managers, and operators seeking to streamline their operations and enhance the efficiency of their systems.

One of the main features of the FS-8700-59 is its extensive protocol support. This gateway is capable of translating between over 130 different protocols, making it a vital tool for managing diverse communication needs across disparate systems. This includes compatibility with popular protocols such as Modbus, BACnet, LonWorks, and many others. As a result, the FS-8700-59 ensures that various devices can communicate effectively, regardless of their original communication format.

The FS-8700-59 is equipped with a powerful processing engine, which enhances its performance and enables real-time data processing. This capability allows the gateway to handle large volumes of data efficiently, ensuring that system integrators can rely on timely communication between devices. Additionally, it features configurable data logging capabilities that help users gather and analyze valuable insights about system performance.

Another significant characteristic of the FS-8700-59 is its user-friendly interface. The device comes with built-in web server technology, allowing users to configure and manage the system easily via a standard web browser. This eliminates the need for specialized software, making it accessible for technicians with varying levels of expertise. Configuration wizards guide users through the setup process, simplifying the deployment of new systems.

Security is also a priority for the FS-8700-59. It incorporates various security protocols to safeguard data transmission, ensuring that sensitive information remains protected from unauthorized access. This feature is increasingly critical as organizations become more reliant on interconnected systems and cloud-based solutions.

The FS-8700-59 is designed for durability and longevity in demanding environments. Its robust casing protects it from dust, moisture, and other environmental factors, making it suitable for a wide range of applications. Overall, the FieldServer FS-8700-59 stands out as a reliable, powerful, and user-friendly solution for integrating diverse building automation systems, making it an indispensable tool for modern facility management.