Maxtor 5120 manual Shock and Vibration, Reliability Specifications

Page 21

PRODUCTSPECIFICATIONS

Shock and Vibration

PARAMETER

OPERATING

NON-OPERATING

 

 

 

Mechanical Shock

20 Gs, 2.0 ms, no errors

200 Gs, 2.0 ms, no damage

Rotational Shock

 

18,000 Rad/sec, no damage

Random Vibration

10 - 45 Hz at 0.004 G2/Hz

10 - 2,000 Hz at 2.15 Grms, no damage

 

48 - 62 Hz at 0.008 G2/Hz

 

 

65 - 300 Hz at 0.004 G2/Hz

 

 

301 - 500 Hz at 0.0006 G2/Hz

 

 

no errors

 

Swept Sine Vibration

 

 

 

0.049 inches double amplitude

 

 

1.0 G peak amplitude (0 - peak)

 

Reliability Specifications

Annual Return Rate

 

< 1.5%

Annual Return Rate (ARR) indicates the average against products

 

shipped. ARR includes all reasons for returns (failures, handling

 

damage, NDF), but does not include inventory credit returns.

Quality Acceptance Rate

 

< 500 DPPM

The quality acceptance rate indicates the percentage of Maxtor

 

products successfully installed by our customers, and/or the number

 

of defective parts per million (DPPM) encountered during the entire

 

installation process.

Start/Stop Cycles

 

50,000 (minimum)

This indicates the minimum cycles for reliable start/stop function at a

 

≥ 60% confidence level.

Data Reliability

 

< 1 per 1014 bits read

Data errors (non-recoverable). Average data error rate allowed with all

 

error recovery features activated.

Component Design Life

 

5 years (minimum)

Component design life is defined as a.) the time period before

 

identified wear-out mechanisms impact the failure rate, or b.) the time

 

period up to the wear-out point when useful component life expires.

3 – 4

Image 21
Contents HA RD Drive Produc T MA Nual 92048U8, 91792U7, 91536U6, 91280U5, 91024U4 and 90750U3 DiamondMax PlusRevisions Manual No U T I O N Before You BeginContents Handling and Installation Product SpecificationsHost Software Interface AT Interface DescriptionInterface Commands Service and SupportGlossary Figures Maxtor Corporation IntroductionManual Organization AbbreviationsConventions Signal ConventionsKey Words NumberingProduct Description DiamondMax Plus 5120 Key FeaturesFunctional / Interface Product FeaturesLogical Block Addressing On-the-Fly Hardware Error Correction Code ECCDefect Management Zone DMZ Software ECC CorrectionCache Management Read-Ahead ModeBuffer Segmentation Automatic Write Reallocation AWRMajor HDA Components Jumper Location/Configuration Subsystem ConfigurationCylinder Limitation Dual Drive SupportDrive Configuration Product SpecificationsPerformance Specifications Models and CapacitiesParameter Standard Metric Physical DimensionsPower Mode Definitions Power Requirements AverageEPA Energy Star Compliance Environmental LimitsShock and Vibration Reliability SpecificationsSafety Regulatory Compliance Radiated Electromagnetic Field Emissions EMC ComplianceCanadian Emissions Statement Hard Drive Handling Precautions Handling and InstallationPre-formatted Drive Important NoticeMulti-pack Shipping Container Unpacking and InspectionPhysical Installation Recommended Mounting ConfigurationRepacking Tools for Installation Handling PrecautionsSystem Requirements Drive Identification InformationHard Drive Identification General RequirementsInstalling 5.25-inch Mounting Brackets and Rails Systems Using Cable SelectInstalling in a Device Bay Mounting Drive in SystemAttaching System Cables Attaching Interface and Power CablesSystem Setup Setting the Bios CmosBios Cmos Parameters Hard Drive Preparation System Hangs During Boot Interface Connector AT Interface DescriptionPin Description Summary Pin Description Table PIN Name Signal Name Signal DescriptionPIO Timing Timing Parameters ModeDMA Timing Ultra DMA Timing Mode MIN MAXSustained Ultra DMA Data In Burst Device Terminating an Ultra DMA Data In Burst Initiating an Ultra DMA Data Out Burst Device Pausing an Ultra DMA Data Out Burst Device Terminating an Ultra DMA Data Out Burst Features Register Error RegisterHost Software Interface Task File RegistersSector Number Register Sector Count RegisterCylinder Number Registers Device/Head RegisterCommand Register Summary Command Name Command Code Parameters Used SDHAlternate Status Register Control Diagnostic RegistersDevice Control Register Digital Input RegisterReset and Interrupt Handling Reset HandlingInterrupt Handling Set Feature Commands Interface CommandsRead Commands Read SectorsRead Verify Sectors Read Multiple Read DMASet Multiple Mode Write CommandsWrite Sectors Write Verify SectorsWrite DMA Write MultipleSet Features Mode Set Feature CommandsPower Mode Commands Sleep Mode Identify Drive Initialization Commands15-8 = PIO data transfer mode = Write Cache enabled Initialize Drive Parameters Seek, Format and Diagnostic Commands Execute Drive DiagnosticFormat Track Execute S.M.A.R.T A.R.T. Command SetService Policy Service and SupportNo Quibble Service SupportMaxFax Service Customer ServiceInternet Glossary Access TimeCylinder Zero Gigabyte GB Logical Block Addressing Read Gate Signal THIN-FILM Media