Eicon Networks C2x Family manual Technical Specifications

Page 16

Technical Specifications

Technical Data

PCI bus compatible (32-bit slot)

Eiconcard

CPU/Memory/Flash

# of HSI Ports

#of ISDN BRI Ports

 

 

 

 

Eiconcard C20

15.36 MHz Motorola 68302

1

N/A

 

512 KB RAM / 512 KB Flash

 

 

 

 

 

 

Eiconcard C21

15.36 MHz Motorola 68302

1

1

 

512 KB RAM / 512 KB Flash

 

 

 

 

 

 

Hardware Installation

Automatic configuration of interrupt request level setting and I/O address

8-bit I/O access

External Interface

Eiconcard

External Interface

Eiconcard C20

One DB-25 femaleport.

 

 

Eiconcard C21

One DB-25 femaleport and one RJ-45 port.

 

 

Performance

64 Kbps full duplex (HSI port)

128 kbps (ISDN BRI port (over the “D” channel or the “B” channels))

Power Requirements

1.25 A at +5 Volts

50 mA at +12 Volts

50 mA at -12 Volts

Environmental Requirements

Operating temperature: 0°C to 50°C

Operating humidity: 0 to 90% (non-condensing)

Barometric operating pressure: 86 to 106 kPascals

Maximum tolerance in power supply variation: +5% to -5%

HSI Ports

DB-25 female connector, supporting V.24 interface (EIA RS-232-C)

NRZ, NRZI, and FM data encoding

Internal or external clocking (DTE or DCE) or split (transmit internal, receive external)

Power Consumption

Warning: Check that power supply will not be overloaded. Maximum power consumption of the board is stated above. The user should check that the total power drawn by the host computer, the Eiconcard C2x, and any other peripherals, does not exceed the capability of the host power supply unit.

16

Technical Specifications

Image 16
Contents Eiconcard C2x Family First Edition July 203-225-01 Table of Contents Page Introduction Hardware FeaturesAbout this Manual Installing the Eiconcard C2x Install the Eiconcard C2xTest the Eiconcard C2x Europe and most countries worldwide Making an Isdn ConnectionNorth America and Others Eiconcard C21 U-interface Connecting to an NT1 Eiconcard C21 S/T-interfaceTermination How do I determine the termination value? Single Isdn DeviceInstalling a Terminating Resistor Multiple Isdn DevicesInterface Specifications Making a V.24 ConnectionV.24 DCE Interface Ccitt #LED Functionality Channel StatusTechnical Specifications Regulatory Information for the USA International Regulatory InformationDeclaration of Conformity FCC Part 68 Notice Regulatory Information for Canada Regulatory Information for Europe EU Declaration of ConformitySafety Status Selv User/Installer Instructions for the United KingdomRegulatory information for Australia Page 203-225-01