G-Technology 0G01868 warranty Appendix a, Raid

Page 17

G-SPEED Product Guide

APPENDIX A

RAID

 

 

 

 

Level

Description

Advantage

Disadvantage

Ideal For…

0

Disk striping

Offers the highest

No fault tolerance -

Content creation

 

 

performance and

failure of one drive

applications

 

 

useable storage

in the array results

 

 

 

capacity

in complete data

 

 

 

 

loss

 

 

 

 

 

 

1

Mirroring

High level of fault

Not the most

Applications in

 

 

tolerance

efficient in regards

which data

 

 

 

to capacity as

security is

 

 

 

useable storage

paramount

 

 

 

space is cut in half

 

 

 

 

 

 

3

Disk striping

High level of

 

Content creation

 

with

read/write

 

applications

 

dedicated

performance, fault-

 

requiring high-

 

parity drive

tolerant, disk

 

performance and

 

 

failure has

 

data security

 

 

insignificant impact

 

 

 

 

on performance

 

 

 

 

 

 

 

5

Disk striping

High read

Disk failure results

File servers,

 

with

performance,

in drop in

database

 

distributed

medium write

performance

applications

 

parity

performance, fault-

 

 

 

 

tolerant

 

 

 

 

 

 

 

6

Disk striping

An extension of

Lower performance

Mission critical

 

with dual-

RAID 5 with a

than RAID 3 or

data

 

distributed

second

RAID 5

 

 

parity

independent

 

 

 

 

distributed parity

 

 

 

 

scheme. High level

 

 

 

 

of fault tolerance.

 

 

 

 

Two drives in the

 

 

 

 

array can fail

 

 

 

 

without data loss.

 

 

 

 

 

 

 

JBOD

Just-a-

Each drive can be

No fault tolerance

Audio

 

bunch-of-

accessed as an

 

applications

 

disks

individual volume.

 

 

 

 

 

 

 

Page 17

Image 17
Contents Speed Speed Product Guide Speed Product Guide Introduction Safety PrecautionsSystem Requirements A. Fibre Channel ScsiInstalling G-SPEED LED IndicatorsSpeed Overview If an Atto Host Bus Adapter was included in your kitFibre Channel Installing the SFP and Optical Cable Installing the Disk Drive ModulesScsi Setting the Scsi ID Scsi Installing the Scsi Cable and TerminatorFormatting G-SPEED Connecting to the G-SPEED GUI Manual ConfigurationInitializing G-SPEED Scsi Configuring G-SPEED Scsi IDWindows XP Users Mac OS X UsersWindows 64 Users Hardware Monitoring Deleting a RAID setSpeed GUI System Control Silencing the Audible AlarmDisable Audible Alarm View Events/Mute Beeper Alert By Mail ConfigTechnical Support Limited WarrantyRAID Appendix a