3.2.3 Taring

Taring functions same as for 3.1 Weighing and taring.

3.2.4 Operating the totalising functions

Press the F key to transfer the weight on the weighing platform to the total memory.

The item counter and the consecutive number are incremented by 1.

Before requesting the next total, the scale must be clipped off at least to the clip off factor defined in Setting mode.

A weight value of 0 or a total without clip off results in "Error 55 Place weight on scale". If the clip off factor = 0, only a brief weight change is required.

Ending the totalising function

The totalising operation is terminated by pressing the key combination INFO, F and Print. At the same time, the totals are printed out with the additional information dependent on the print template, or they are transferred and deleted as data record.

3.2.5 Selection options for total display

Function description in the manual.

-Display, print and clear total.

-Only display totals.

3.2.6 Clip off factor when totalising

(no function when batching)

In Setting mode, you can define (see manual) whether the scale must be clipped off each time you place an individual piece by 1 to 30 increments.

If the scale is not clipped off, the weight unit is not accepted in the total memory. This prevents operations such as saving an item twice.

3.2.7 Automatic totalising

See the description of the function in the CD manual.

19

Image 19
Contents 3020 English ContentsDescription of the appliance Technical dataProgram settings Terminal Scale Data processing Service Installation and commissioningOperating concept, keys and display symbols Setting modeNavigation in Setting mode Program modeFunction key Input and control keys Symbol for standstill Symbols in the display symbol barDisplay Basic functions Power on/offSelecting a program Approvable scale ZeroingX10 display Zero trackingOrganisation data identifiers Content inputDescription input Unit Switching between scalesActivating input boxes Input procedure Numerical boxesAlphanumeric input Types of input boxDisplay view Application programsSelecting an application program Weighing and taringManual taring Weighing without taringTaring by manual tare input Automatic taring Entering tare weights into the fixed tare value memoryAdditive tare Provisional tareCalling up the list of fixed tare value memories for taring Changing or overwriting a fixed tare value memoryClearing an existing fixed value Display options with the Info key Error message when taringError When you press the Info key, you have the following optionsFunction key Totalising and batchingTotal memory with several connected scales Selection options for total display Clip off factor when totalisingTaring Operating the totalising functionsDisplaying the current totals Print-command keysAssigning and clearing the consecutive number Item counterCounting function Determining the reference weight Function key F RefCounting Counting display viewTerminate the count operation Displaying the reference weightWeight display during the counting operation Fixed value memory for reference weightsCounting with several weighing platforms Check display view CheckingFurther information English English Soehnle Professional GmbH & Co. KG