Soehnle 7711 manual Safety instructions, Use of additional devices, Applicator, Operating concept

Page 4

ENGLISH

BED SCALE 7711

Safety instructions

Before putting the appliance into use,

please read with care the information given in the Operating Instructions. They contain important in- structions for installation, intended use and mainte- nance of the appliance. The manufacturer shall not be liable if the following instructions are not observed:

In case the electrical components are used under increased safety requirements, compliance with the appropriate regulations is compulsory. Never perform work on the appliance while the power is switched on. Improper installation will render the warranty null and void. Ensure the voltage marked on the power supply unit matches your mains power supply. The device is designed for use within buildings. Observe the permissible ambient temperatures for use (Tech­ nical Information). The device meets the requirements for electromagnetic compatibility. Do not exceed the maximum values specified in the applicable stand- ards. If you have any problems, contact your local Soehnle Professional service partner.

Warning: A change of the medicine device is pro- hibited. This device may not be changed without the manufacturer's authorisation. If the medicine device is changed, appropriate analysis and examination must be undertaken to ensure a safe continued use.

Use of additional devices

Only additional appliances (printer, computer) may be connected to the serial data port if they conform to European Standard EN 60601-1 or a suitable dis- connecting device is connected in series.

Applicator

The scale does not have an applicator. No part is in- tended for direct contact with the patient. Leakage currents were measured on the weighing devices in compliance with classification of Type B applicators.

Operating concept

The appliance is operated by means of the keypad. The keys are assigned with different functions de- pending on the various modes.

Maintenance and service

The measuring inspection test was performed during the initial calibration process in production. Further regular measuring inspection tests (recalibration) must be carried out by the calibration authorities respon- sible in compliance with national regulations. Repairs may only be carried out by a centre authorised by Soehnle Professional using genuine spare parts. The medicine device is equipped with a non-de- tachable power line. The power line may not be ex- changed by maintenance personal.

Cleaning

Before cleaning, disconnect the appliance from the mains by removing the power plug from the wall socket. Only clean the appliance using a moist cloth. On no account may water be allowed to enter into the appliance. Disinfectant may only be applied to the membrane keyboard for the display. It is prohi­ bited to spray the appliance and the power plug. The following disinfectants are permitted: methy­ lated spirits, Isopropanol; 2% Kohrsolin, 1% aqueous Sokrena solution, 5% Sagrotan or 5% Gigasept.

4

Image 4
Contents BED Scale Contents EnglishAllgemeine Informationen Intended useCE sign ClassificationSafety instructions Maintenance and serviceCleaning Use of additional devicesWarranty/liability DisposalEnglish Power-on / Power-off Installing the scale elementsPutting Into Operation Radio link Power-offCharging the batteries Charge run time Display of link stateRecommendation Input and Control Keypad for input and controlAlphanumeric input Input procedureTypes of input box Indicator display Icons/characters Setting Mode Keypad in Setting modeProgram settings Terminal Scales Data Processing Service Overview of menu navigationCalling up Setting mode Inputs in Setting modeSettings in Setting mode Settings in Program Settings menuReset terminal User passwordDate/time Organisation dataPower-on zeroing Weighing and taring FunctionsManual zeroing X10 times 10 displayWeighing with manually entered tare Weighing with stored tare valuesShowing the value in the tare memory Each memory location has aCorrecting values Calling up the list of fixed tare value memories for taringProvisional tare/dialysis function Using the dialysis functionClearing a tare value Error message when taring Displaying the tare memoryBMI function Hold functionPrint Connection options factory settingInfo about printer Default print templates, factory setting Print-command conditionsProgramming the F key Following conditions can be assigned to print templatesZeroing not possible Error numbers Cause / Remedy / InfoTaring no possible Place weight on scale Value above zero range limitOverload UnderloadOther technical data Technical dataInstructions for installing the scale Electronic nameplate and calibration counter Explanations of labels and iconsSymbol for EU calibration 80mASCALES, System Solutions and Special Developments Soehnle Professional GmbH & Co. KG