SECTION 4 – INSTALLATION

4-1. Selecting a Location

18 in

(460 mm)

18 in

(460 mm)

18in

(460 mm)

Position unit so air can circulate.

For information about sources of high-frequency see Section 8.

For carts and caster kits see back of book or contact your distributor.

ST-158 075

4-2. Typical Stick Connections

Y Turn Off power before mak- ing connections.

1 Electrode Holder

2 Work Clamp

Connect to receptacle as shown.

1

2

ST-157 858-A

OM-303 Page 12

Image 16
Contents Description OM-303155795NProcesses From Hobart to You Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersSignification des symboles Consignes DE Securite Lire Avant UtilisationUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un incendie ou une explosionLE Bruit peut affecter l’ouïe Risque D’INCENDIE OU LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresInformation sur les champs é lectromagné tiques Principales normes de sé curitéConsignes relatives aux stimulateurs cardiaques General Precautionary Label DefinitionsIntroduction Symbols And DefinitionsIncluded with Your Unit Specifications Duty Cycle ChartVolt-Ampere Curves Hertz ModelsInstallation Turn Off power before mak- ing connectionsSelecting a Location Typical Stick ConnectionsTypical TIG Connections Electrical Service Guide Connecting Input PowerOperation ControlsExample of Front Panel Amperage Control Example of Remote Amperage ControlGtaw Welding Amperage Range AC Low AC HighProcess and Material Thickness Guide Label Routine Maintenance Maintenance and TroubleshootingTroubleshooting Electrical Diagrams Circuit DiagramIncorrect Installation High FrequencyWelding Processes Requiring High Frequency Weld ZoneMetal Building Correct InstallationMetal Building Requirements Parts List Main AssemblyDia Part Description Mkgs Quantity Figure -1. Main Assembly Page Page Service SupportContact your Distributor for Hobart Welding Products