4From the back of the computer, remove the five M2.5 x 5-mm screws labeled with the "circle D." There are two screws on the right hinge and three screws on the left hinge.
5Open the display assembly approximately 180 degrees and support the display assembly so it does not open past this position.
6Remove the two M2 x 3-mm screws that secure the EMI shield bracket to the system board assembly.
7Remove the flex cable EMI shield retention bracket that covers the display-feed flex cable connector on the system board.
8Pull straight up on the display-feed flex cable connector to disconnect the connector from the system board (see "Display Assembly").
9Lift the display assembly from the bottom case assembly.
NOTICE: When reconnecting the display-feed flex cable connector to the system board, push down on the top left and right ends of the connector (see "Reconnecting the Display-Feed Flex Cable Connector"). Pressing on the center of the connector may damage resistors and compromise EMI protection in the system.
Re c o n n e c t i n g t h e D i s p l a y - Fe e d F l ex C a b l e C o n n e c t o r