4.Initializing virtual disks

5.Performing Background Initialization

6.Creating Secured Virtual Disks

7.Securing Pre-Existing Virtual Disks e. Managing Controllers through BIOS

1.Enabling Boot Support

2.Enabling Boot Support For A BIOS-Enabled Controller

3.Enabling BIOS Stop On Error

4.Enabling Auto Import

2.Install the operating system. For more information, refer to your operating system documentation.

3.Install the operating system drivers for PERC 9.

• If your operating system is Windows, install the Windows drivers. For more information, see Windows driver installation.

• If your operating system is Linux, install the Linux drivers. For more information, see Linux driver installation.

4.Additionally, you can install and use OpenManage Storage Services to manage the PERC card(s), after the operating system is installed.

Setting up the system with the PERC card and the operating system pre-installed

1.Use any of the PERC management applications to create the virtual disks and RAID configurations you require using the procedures listed below:

a.Importing Or Clearing Secured Foreign Configurations And Secure Disk Migration

b.Manage physical disks.

1.Creating Global Hot Spares

2.Creating Security Key

3.Converting a RAID disk to a Non-RAID disk. For more information, see Controller management.

4.Converting a Non-RAID disk to a RAID disk. For more information, see Controller management.

c.Creating virtual disks

Setting up virtual disks

d.Managing virtual disks

1.Setting up virtual disks

2.Checking Data Consistency

3.Managing Preserved Cache

22

Image 22
Contents Dell PowerEdge RAID Controller Perc 9 User’s Guide Page Contents Driver installation Deploying the Perc cardBios Configuration Utility UEFI/HII RAID configuration utility Security key and RAID management100 Appendix RAID description Getting helpFeatures of Perc H330 adapter card OverviewFeatures of Perc H330 mini monolithic card Features of Perc H730 card Features of Perc H730/H730P mini monolithic card Features of Perc H730P adapter card Features of Perc H830 adapter card Supported operating systemsPerc card specifications Perc H330 Perc H730 Perc H730P Perc H830SAS Comprehensive embedded management Management applications for Perc cardsDell OpenManage Storage Management Related documentation Getting started with your Perc card Creating Global Hot Spares Creating Security KeyCreating Global Hot Spares Creating Security Key Creating virtual disks Setting up virtual disks Manage physical disks Creating Global Hot Spares Creating Security Key Page T10 protection information FeaturesPerc 9 personality management Enabling T10 PIPhysical disk power management Secure firmware updateImproved RAID 10 configuration 4KB block size disk drivesTypes of virtual disk initialization Configured spin down delayFull initialization Consistency checks Background initializationFast initialization Disk roaming Using disk roamingConfiguring FastPath-capable virtual disks FastPathVirtual disk migration Migrating virtual disksVirtual disk read cache policies Virtual disk write cache policiesConditions under which write-back is employed Reconfiguration of virtual disks Or more Yes Removes Redundancy While increasing Capacity Fault tolerance Smart FeaturePatrol Read Using persistent hot spare slotsPhysical disk failure detection Physical disk hot swapping Using replace member and revertible hot sparesController cache preservation Battery Transparent Learn Cycle Non-RAID disks supportSelect OK Deploying the Perc card Removing the Perc 9 adapterBattery cable connector Perc 9 card SAS cables Installing the Perc 9 adapter Removing the Perc 9 mini monolithic controllerReplacing the battery of a H730P mini monolithic card Removing and installing the Perc 9 mini monolithic cardRemoving the battery carrier Installing the Perc 9 mini monolithic controller Removing the batteryRemoving a H730P slim card Replacing the battery of a H730P slim card Removing and installing a H730P slim cardRemoving the battery Installing a H730P slim card Removing the Perc 9 mini blade controllerReplacing the tethered battery of a Perc 9 mini blade card Removing and installing the Perc 9 mini blade controllerRemoving the battery carrier Removing the battery from the battery carrier Installing the battery into the battery carrier Installing the Perc 9 mini blade controller Replacing the battery carrierRemoving the Perc FD33xD Card Replacing the battery of a Perc FD33xD card Removing and installing the Perc FD33xD cardInstalling the Perc FD33xD card Page Creating the device driver media Driver installationDownloading drivers from the Dell support website Windows driver installation Linux driver installation Page Entering the Bios Configuration Utility Bios Configuration UtilityExiting the Configuration Utility Menu navigation controls Setting up virtual disks For more information, see Managing dedicated hot sparesParameters description Bios Configuration Utility menu options Virtual disk managementPage Virtual disk actions Physical disk management PD Mgmt Physical disk actionsRebuild Controller management Ctrl MgmtController management actions Virtual Disk Management Foreign configuration viewCreating virtual disks Selecting virtual disk parameters Initializing virtual disksChecking data consistency Running a data consistency checkPage Break mirror Break mirror in Bios configuration utility Managing preserved cacheManaging dedicated hot spares Deleting virtual disksPhysical Disk Management Clearing the configurationSetting LED blinking Deleting disk groupsRemoving global or dedicated hot spares Creating global hot sparesReplacing an online physical disk Stopping background initialization Restrictions and limitationsPerforming a manual rebuild of an individual physical disk Enabling boot support for a BIOS-enabled controller Enabling boot supportController Management Enabling auto import Enabling Bios stop on errorDisabling Bios stop on error Disabling auto importRestoring factory default settings Exiting the Uefi configuration utility UEFI/HII RAID configuration utilityEntering the Uefi configuration utility Navigating to Dell Perc 9 configuration utilityConfiguration management Converting physical disks to non-RAID disk Creating profile based virtual disksConverting physical disks to RAID capable disk Viewing disk group propertiesRestoring factory settings for the controller Managing foreign configurations on a RAID controllerDeleting existing configurations on a RAID controller Saving controller eventsEnabling security for the controller Switching the controller to HBA modeSaving debug log Viewing virtual disk properties Switching the controller to RAID modeViewing physical disks associated with a virtual disk Hardware components management Viewing battery propertiesViewing physical disk properties Viewing physical disks associated with an enclosure Security key and RAID management Security key management in the Bios configuration utilitySecurity key implementation Creating a security key Local Key Management LKMChanging the security key Creating secured virtual disks Deleting a security keySecuring pre-existing virtual disks Page Instant secure erase Discovery error message TroubleshootingBios configuration utility error messages Extra enclosure error messageMissing virtual disks error message Previous configuration of disks removed error messageDirty cache data error message Drive Configuration Changes Error Message Bios disabled error messageAdapter at baseport not responding error message Virtual disks degraded error message Virtual disks offline error messageVirtual disks partially degraded error message Foreign configuration found error message Memory or battery problem error messageFirmware fault state error message Foreign configuration not found in ctrl R error messageConfigured disks removed or not accessible error message Previous configuration cleared or missing error messageInvalid SAS topology detected error message Degraded state of virtual disksSecured foreign import errors Memory errorsSecurity key errors Preserved Cache StateGeneral Issues Physical disk issuesMultiple disks become inaccessible Unable to rebuild a fault tolerant virtual diskFatal error or data corruption reported Physical disk displayed as blockedRebuilding a failed physical disk Virtual disk fails during rebuild using a global hot spareVirtual disk fails rebuild using a dedicated hot spare Physical disk takes a long time to rebuildSmart errors Replace member errorsTarget disk fails Linux operating system errorsSource disk fails during replace member operation General disk failsUnable to register Scsi device error message Disk Carrier LED IndicatorsUefi error messages Unhealthy Status of the DriversCorrective Action RAID terminology Appendix RAID descriptionSummary of RAID levels Disk stripingDisk mirroring Spanned RAID levelsParity data Example of Distributed Parity RAIDContacting Dell Locating your system Service TagGetting help Documentation feedback