Dell M620 owner manual Installing a Mezzanine Card, Installing and Removing a Mezzanine Card

Page 39

5.Close the retention latch.

6.Close the blade.

7.Install the blade in the enclosure.

Figure 9. Installing and Removing a Mezzanine Card

1.mezzanine cards (2)

2.Fabric B mezzanine card slot

3.Fabric C mezzanine card slot

4.retention latch

Installing A Mezzanine Card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.Remove the blade from the enclosure.

2.Open the blade.

3.Open the retention latch by pressing the ridged area on the latch with your thumb and lifting the end of the latch.

4.If present, remove the connector cover from the mezzanine card bay.

NOTE: Hold the mezzanine card by its edges only.

5.Mezzanine cards are designed to fit in either card slot. Rotate the card to align the connector on the bottom of the mezzanine card with the corresponding socket on the system board.

39

Image 39
Contents Regulatory Model HHB Regulatory Type HHB003 Dell Inc. All Rights Reserved Contents Installing The Cooling Shroud Technical Specifications System Messages Troubleshooting Your SystemUsing System Diagnostics Jumpers And Connectors143 Using USB Diskette or USB DVD/CD Drives Front-Panel Features And IndicatorsSeconds Hard-Drive/SSD Indicator PatternsDrive-Status Condition Indicator Pattern OffOther Information You May Need Page Choosing The System Boot Mode Using The System Setup Navigation Keys Entering System SetupSystem Setup Options Responding To Error MessagesSystem Information Screen System Bios ScreenProcessor Settings Screen Memory Settings ScreenBoot Settings Screen Sata Settings ScreenIntegrated Devices Screen Serial Communications Screen System Security Screen System Profile Settings ScreenMiscellaneous Settings System And Setup Password Features Assigning a System And/Or Setup PasswordMenu Item Description Report Keyboard Using Your System Password To Secure Your System Entering The Uefi Boot Manager Operating With a Setup Password EnabledUsing The Boot Manager Navigation Keys IDRAC Settings Utility Boot Manager ScreenEmbedded System Management System Setup Main Menu page, click iDRAC Settings Entering The iDRAC Settings UtilityRemoving And Installing a Blade Recommended ToolsRemoving The Blade Removing or Installing the Blade Installing The BladeOpening The Blade Opening And Closing The BladeClosing The Blade Inside The BladeRemoving The Cooling Shroud Cooling ShroudOperating Frequency in MT/s Maximum Dimm Rank Channel Installing The Cooling ShroudSystem Memory Dimm TypeMemory Socket Locations ProcessorMode-Specific Guidelines General Memory Module Installation GuidelinesProcessor Heat Number of DIMMs Configuration Type Sink Watts Serviceability RAS FeaturesAdvanced ECC Lockstep Sample Memory ConfigurationsDIMMs Speed System Capacity Dimm Size Number Organization1R x8, 1333 MT/s Removing Memory Modules Installing Memory Modules Mezzanine Card Installation Guidelines Module Mezzanine CardsRemoving a Mezzanine Card Installing and Removing a Mezzanine Card Installing a Mezzanine CardReplacing The SD Card Management Riser CardReplacing The Internal USB Key Internal USB KeyReplacing The SD vFlash Card SD vFlash CardRemoving The Network Daughter Card/LOM Riser Card Network Daughter Card/LOM Riser CardInstalling The Network Daughter Card/LOM Riser Card ProcessorsRemoving a Processor Installing and Removing a Heat Sink Open 1st label Socket-release lever Pin-1 corner of processor Reinstalling a Installing a ProcessorHard Drive/SSD Installation Guidelines Hard Drives/SSDsRemoving a Hard Drive/SSD Shutdown Procedure For Servicing a Hard Drive/SSD Installing a Hard Drive/SSDConfiguring The Boot Drive Installing a Hard Drive/SSD In a Hard-Drive/SSD CarrierRemoving a Hard Drive/SSD From a Hard-Drive/SSD Carrier Removing The Hard-Drive/SSD Backplane Hard-Drive/SSD BackplaneInstalling The Hard-Drive/SSD Backplane System BoardRemoving The System Board Removing and Installing the System Board Installing The System BoardReplacing The Nvram Backup Battery Nvram Backup BatteryRemoving The PCIe Extender Card/Storage Controller Card Storage Controller CardInstalling The PCIe Extender Card/Storage Controller Card Page Troubleshooting Your System Troubleshooting USB Devices Troubleshooting Hard DrivesTroubleshooting An Internal SD Card Troubleshooting ProcessorsTroubleshooting The Blade System Board Troubleshooting The Nvram Backup Battery Dell Online Diagnostics Dell Embedded System Diagnostics When To Use The Embedded System DiagnosticsRunning The Embedded System Diagnostics Running Embedded System Diagnostics From An External Media System Diagnostic ControlsLeast one event description is recorded Jumper Setting Description System Board Jumper SettingsConnector Description System Board ConnectorsDisabling a Forgotten Password Page Connectors MemoryDrives Environmental BatteryMezzanine Cards VideoOperating temperature range Page Removing LCD Messages System Error MessagesLCD Status Messages Viewing LCD MessagesAMP0303 Message AMP0301 MessageLCD Message AMP0302 MessageAMP0309 Message AMP0306 MessageAMP0307 Message AMP0308 MessageAMP0314 Message AMP0310 MessageAMP0312 Message AMP0313 MessageAMP0319 Message AMP0315 MessageAMP0316 Message AMP0318 MessageASR0000 Message AMP0320 MessageAMP0321 Message AMP0322 MessageASR0100 Message ASR0002 MessageASR0003 Message ASR0008 MessageASR0106 Message ASR0103 MessageASR0104 Message ASR0105 MessageController Due to thermal issuesCBL0006 Message BAT0015 MessageBAT0017 Message BAT0019 MessageCPU0005 Message CPU0002 MessageCPU0003 Message CPU0004 MessageCPU0100 Message CPU0008 MessageCPU0010 Message CPU0023 MessageCPU0202 Message CPU0104 MessageCPU0200 Message CPU0201 MessageCPU0203 Message CPU0204 MessageCPU0700 Message CPU0701 Message CPU0702 MessageCPU0703 Message CPU0803 Message Exception is external to the processorCPU0801 Message CPU0802 MessageCPU0816 Message CPU0804 MessageCPU0805 Message CPU0806 MessageHWC1006 Message HWC1001 MessageHWC1002 Message HWC1005 MessageHWC3000 Message HWC2006 MessageHWC2008 Message HWC2011 MessageCPU Issue persists, see Getting HelpHWC4015 Message Link Tuning error detected Details HWC4000 MessageHWC5010 Message HWC5004 MessageHWC5006 Message HWC5008 MessageNormal or warning state HWC7002 MessageState HWC7004 MessageLNK2700 Message HWC7008 MessageHWC7010 Message HWC7012 MessageMEM0005 Message MEM0002 MessageMEM0003 Message MEM0004 MessageMEM0702 Message MEM0010 MessageMEM0022 Message MEM0701 MessageMEM1206 Message MEM1012 MessageMEM1016 Message MEM1205 MessageOSE0000 Message MEM1214 MessageMEM7002 Message MEM8000 MessageOSE1005 Message PXE boot failed Action OSE1001 Message Failed to boot from a ActionIs bootable. See system video for additional information OSE1003 Message Failed to boot from C ActionPCI1308 Message PCI1302 MessagePCI1304 Message PCI1306 MessagePCI1322 Message PCI1316 MessagePCI1318 Message PCI1320 MessagePCI1350 Message PCI1344 MessagePCI1346 Message PCI1348 MessagePCI2002 Message PCI1360 MessagePCI1362 Message PCI2000 MessagePCI3010 Message PCI3004 MessagePCI3006 Message PCI3008 MessagePDR1001 Message PDR0001 MessagePDR0002 Message PDR0016 MessageMemory for system operation ConfigurationsPDR1024 Message Correct drive typeSystem Post Timer during PostSeat processors Persists, see Getting Help Minimum configurationPST0196 Message Incorrect memory configuration Have been removedPSU0002 Message PST0254 MessagePST0256 Message PSU0001 MessageIssues with the input source Manual or on the power supply itselfPower supply Circuit breaker faultPSU1203 Message PSU0031 MessagePSU1201 Message PSU1202 MessageSystem may shutdown System power inventory changeConfiguration and power consumption ChangedRFM1003 Message PWR1006 MessagePWR1007 Message PWR1008 MessageRFM1016 Message RFM1006 MessageRFM1008 Message RFM1014 MessageProperly RFM1024 Message Removable Flash Media is offline DetailsA copy operation that is in-progress Idsdm cannot use a write-protected cardRFM2004 Message RFM1205 MessageRFM2001 Message RFM2002 MessageSystem performance may be degraded Review installation documentationSEC0001 Message Drive bay is open Details Performance may be degradedSEC0041 Message System configurationMay have been comprised Code = 20HPassword policies SEL0002 Message Logging is disabled DetailsDisabled by the user Older events may be overwritten and lost Appear if the user disabled event loggingPower. If problem persists call support By the userUser to select a boot source SEL1300 Message No bootable media found DetailsConfiguration settings are applicable SEL1302 Message Non-bootable diskette detected DetailsGroup Action Upgrade the management softwareCMC firmware versions match SEL1502 MessageSlot number and CMC Bios in slot number and CMCPlease update the firmware SWC4004 MessageTMP0107 Message TMP0103 MessageTMP0104 Message TMP0106 MessageTMP0113 Message TMP0109 MessageTMP0110 Message TMP0112 MessageTMP0121 Message FailuresTMP0115 Message FailedTMP0100 Message Details Ambient air temperature is too warm or cool ActionVLT0100 Message TMP0130 MessageTMP0132 Message TMP0134 MessageVLT0102 Message VLT0103 MessageVLT0104 Message VLT0200 Message VLT0201 MessageVLT0202 Message VLT0203 Message VLT0204 MessageVLT0206 Message VLT0207 Message VLT0208 MessageVLT0209 Message VLT0210 Message VLT0212 MessageVLT0213 Message VLT0214 Message VLT0215 MessageVLT0216 Message VLT0218 Message VLT0219 MessageVLT0220 Message VLT0221 Message VLT0222 MessageVLT0224 Message VLT0225 Message VLT0226 MessageVLT0227 Message VLT0228 Message VLT0230 MessageVLT0231 Message VLT0232 Message VLT0233 MessageVLT0234 Message Alert Messages Diagnostic MessagesContacting Dell Getting Help
Related manuals
Manual 12 pages 5.14 Kb Manual 140 pages 32.84 Kb Manual 133 pages 45.77 Kb

M620 specifications

The Dell M620 is a high-performance blade server designed to deliver exceptional computing power and efficiency for enterprise applications. As part of the Dell PowerEdge M-Series lineup, the M620 is known for its flexibility, scalability, and robust feature set, making it an ideal choice for data centers looking to optimize their server infrastructure.

One of the main features of the Dell M620 is its advanced processing capabilities. It supports dual Intel Xeon E5-2600 series processors, which enable users to take advantage of the latest multi-core technology to handle demanding workloads. With support for up to 768 GB of RAM, the M620 ensures efficient memory allocation for resource-intensive applications, enhancing overall performance.

The blade server boasts a modular design that allows it to fit seamlessly into the Dell PowerEdge M1000e chassis, which can house multiple blade servers. This design not only saves physical space but also optimizes power and cooling resources, significantly reducing total cost of ownership. The M620's thermal efficiency is further enhanced by its intelligent fan control, which adjusts airflow based on workload requirements, ensuring optimal operating conditions.

In terms of storage, the Dell M620 offers flexibility with support for up to two hot-swappable hard drives. This feature facilitates easy upgrades and maintenance, allowing organizations to manage data growth efficiently. The server also supports the latest RAID technology, which provides data redundancy and enhances reliability, essential for critical business operations.

Networking capabilities are another standout feature of the M620. It provides multiple options for integrated networking, including support for up to four 1Gb Ethernet ports or 10Gb Ethernet options. This enables fast and reliable connectivity, which is crucial for data-intensive applications and virtualization environments.

Security is also a key consideration in the design of the Dell M620. It comes equipped with various security features, including Trusted Platform Module (TPM), secure BIOS, and systems management tools, ensuring a secure computing environment.

Overall, the Dell M620 blade server combines powerful processing capabilities, expandable memory, efficient design, versatile storage options, and robust networking solutions. These characteristics make it a compelling choice for organizations seeking to enhance their IT infrastructure, drive innovation, and meet the challenges of today’s digital landscape. With Dell's commitment to quality and performance, the M620 continues to be a valuable solution for enterprise customers.