Zone 1
server 1 server 2 | server 3 | server 4 |
| PowerVault |
| Fibre Channel |
| bridge |
PowerVault | PowerVault |
56F Fibre | 56F Fibre |
Channel | Channel |
switch 1 | switch 2 |
| PowerVault |
| tape library |
PowerVault | PowerVault |
65xF 1 | 65xF 2 |
Zone 2
Figure 1-9. Example of a Two-Cluster Configuration Sharing a PowerVault 130T DLT Library
The example shown in Figure
•Zone 1 — server 1, server 2, PowerVault 65xF storage system (number 1), and Fibre
•Zone 2 — server 3, server 4, PowerVault 65xF storage system (number 2), and Fibre
Switch fabric 2 comprises switch 2:
•Zone 1 — server 1, server 2, and PowerVault 65xF storage system (number 1)
•Zone 2 — server 3, server 4, and PowerVault 65xF storage system (number 2) To implement the zoning in the preceding configuration, perform the following steps:
1.Ensure that the PowerVault 65xF storage system (number 2), server 3, and server 4 are turned off.
2.Configure zone 1 on switch fabric 1 and zone 1 on switch fabric 2.
3.Turn on the PowerVault 65xF storage system (number 2), server 3, and server 4.
4.Configure zone 2 on switch fabric 1 and zone 2 on switch fabric 2.
See the Dell PowerVault 5xF Switches Zoning Guide for more information on configur- ing zones on the Fibre Channel switches.