Graco 15V336, 15V337 Network Local Network Configuration, Manual Configuration

Page 15

Network

Local Network Configuration

In a local network mode, the AWI module is configured for a closed network that includes a PC and Graco devices. In this mode, AWI is set to a static IP address (192.168.178.200). The system enables DHCP and DNS servers.

1.On the Settings Tab, in the Network section, select Local network.

2.Click Save, and when the confirmation screen appears, click Confirm.

NOTE: Be sure there is no physical connection to another existing LAN in local network mode. It will lead to a possible disturbance to the network operation.

Manual Configuration

In manual configuration mode, the AWI module can be configured to operate on an existing local area network (LAN). In this mode, the AWI is assigned to a static IP address, gateway, and netmask chosen by the user. The system will disable DCHP and DNS servers. In addition, a virtual network interface will be enabled (IP aliasing, 192.168.178.200/255.255.255.0).

System Configuration

1.To change to a manual network configuration, connect and configure the AWI in local network mode. See Connections, page 6 and Computer Configuration, page 8 .

2.On the Settings Tab, in the Network section, select Manual configuration.

3.Enter the IP address, gateway and netmask. Contact your IS system administrator for assistance.

NOTE: Make sure there is no other device on the network with a conflicting IP configuration.

4.Click Save.When the confirmation page appears, click Confirm.

Once the new settings are confirmed, the AWI will disconnect the user computer. Reconnect the AWI and computer. Reconfigure the user computer to match the new LAN configuration. You can then login to the AWI using the newly assigned IP address.

NOTE: If you change the addresses in this section, be certain that the new adresses will work and be sure to write them down. These addresses provide access to the AWI program. If you change these addresses and cannot remember the new ones, you will not be able to access any AWI screens.

332459A

15

Image 15
Contents Manual. Save these instructions Important Safety InstructionsFire and Explosion Hazard Equipment Misuse Hazard Related Manuals Overview LocationMounting Key Conections Installation Example Supplied in AWI Module Accessories or User-Supplied ComponentsConnections Installation Example Set Up an Automatic IP Address Set Up IP Address Manually System Initialization Password Recovery System Configuration Settings TabLanguage Upgrade AWIClick Upgrade System TimeAccounts Manual Configuration Network Local Network ConfigurationRecover IP Settings Network Tab System Configuration System Configuration Line3 Add or Remove GatewaysAdd or Remove Devices To Manual Materials TabReplace AWI Board Wiring Diagrams Kit 15V337 Advanced Web Interface ModulePart Description Qty Kit 15V336 Advanced Web Interface Server Hub PartDescriptionQty Cables AccessoriesDimensions Graco Information Graco Standard Warranty