System Configuration

Recover IP Settings

If you have lost your IP settings and can no longer access screens, you can force a network reset to configure the AWI to the default Local Network Configuration.

NOTICE

To avoid damage to the circuit board, wear Part No. 112190 grounding strap, and ground appropriately.

1.Turn off power to the AWI unit.

2.On the AWI computer board (TS-7800), remove the jumper from JP1. Put it on DIO pin pair 1 (noted by dot).

JP-1

DIO-1

NOTICE

Be certain you move the jumper only to DIO pin pair 1. Other placement of the jumper will damage the board.

3.Power up the AWI and wait one minute, then power it down again.

4.Remove the jumper from DIO 1. Put it back on JP1.

5.Power up the unit. The system will operate in default Local Network Configuration. To login, type http://gracoawi or http://192.168.178.200 in the browser address bar. Press Enter.

6.The Login screen appears. Log in with the login and password you set up. Your settings will be intact.

ti21708a

16

332459A

Image 16
Contents Important Safety Instructions Manual. Save these instructionsFire and Explosion Hazard Equipment Misuse Hazard Related Manuals Location OverviewMounting Accessories or User-Supplied Components Key Conections Installation Example Supplied in AWI ModuleConnections Installation Example Set Up an Automatic IP Address Set Up IP Address Manually System Initialization Password Recovery Settings Tab System ConfigurationUpgrade AWI Click UpgradeSystem Time LanguageAccounts Network Local Network Configuration Manual ConfigurationRecover IP Settings Network Tab System Configuration System Configuration Add or Remove Gateways Line3Add or Remove Devices Materials Tab To ManualReplace AWI Board Kit 15V337 Advanced Web Interface Module Wiring DiagramsPart Description Qty Part Kit 15V336 Advanced Web Interface Server HubDescriptionQty Accessories CablesDimensions Graco Standard Warranty Graco Information