Graco 15V336, 15V337 important safety instructions Overview, Location, Mounting

Page 5

Installation

Installation

Overview

NOTE: Refer to this manual first, then look in your system manual for information specific to your system

(the Informer, for example, or the ProControl 1KE). ProMix 2KS and ProMix 3KS Users: Please refer to Manual 313386.

The Advanced Web Interface (AWI) is an accessory that works with many Graco devices and gateways. The AWI allows communication with a personal computer (PC) over an ethernet. With the AWI, users can view and change system setup parameters and create reports from a remote PC. This manual contains installation and setup information common to all devices. It includes sections on how to configure your computer, initialize the system, configure the main system settings, and set up your network.

NOTE: Screen views in this manual are shown using Microsoft Windows 7.

Location

The AWI module may be installed in a local network of Graco devices, such as a network of ProControl 1KEs. It also may be installed in a Local Area Network (LAN).

Do not install equipment approved only for non-hazardous location in a hazardous area.

Install the AWI near your system’s control module, in a non-hazardous area.

Mounting

1.See Dimensions, page 27.

2.Ensure that the wall and mounting hardware are strong enough to support the weight of the equipment, fluid, hoses, and stress caused during operation.

3.Using the equipment as a template, mark the mounting holes on the wall at a convenient height for the operator and so equipment is easily accessible for maintenance.

4.Drill mounting holes in the wall. Install anchors as needed.

5.Bolt equipment securely.

332459A

5

Image 5
Contents Manual. Save these instructions Important Safety InstructionsFire and Explosion Hazard Equipment Misuse Hazard Related Manuals Mounting OverviewLocation Connections Key Conections Installation Example Supplied in AWI ModuleAccessories or User-Supplied Components Installation Example Set Up an Automatic IP Address Set Up IP Address Manually System Initialization Password Recovery System Configuration Settings TabClick Upgrade Upgrade AWISystem Time LanguageAccounts Manual Configuration Network Local Network ConfigurationRecover IP Settings Network Tab System Configuration System Configuration Line3 Add or Remove GatewaysAdd or Remove Devices To Manual Materials TabReplace AWI Board Part Description Qty Wiring DiagramsKit 15V337 Advanced Web Interface Module DescriptionQty Kit 15V336 Advanced Web Interface Server HubPart Cables AccessoriesDimensions Graco Information Graco Standard Warranty