UltraViolet Devices V-Flex specifications Installation of the Power Junction Module, Raceway

Page 8

20.After installation of the last Lamp Module on the side opposite of the Power Junction Module, route the power wires from the last Lamp Module installed through the feed through hole connecting the wire raceway from either side. Do not install lamps at this stage. (see Figure 3c for example of completely wired system)

Figure 3c

INSTALLATION OF THE POWER JUNCTION MODULE

Figure 4a

21.Remove Power Junction Module cover.

22.Thread wires from last Lamp Module installed on each side through Power Junction Module strain relief (See Figure 4a).

23.Attach Power Junction Module to support with screws provided (2) as shown in Figure 4a.

24.Pull wires through strain relief until slack is removed and tighten strain relief screws to secure the wires entering the Power Junction Module

25.Cut and strip wires, 3/8", and insert into respective WAGO connector terminals (black-black, white-white, green-green), as required.

26.Fold cables into Power Junction Module enclosure.

PREPARATION OF THE WIRE/RACEWAY COVER

Raceway

19-2021 Rev E, 06/05/07

8

Image 8
Contents Flex Table of Contents Specifications Power RatingsTemperature Ratings Power ConsumptionProduct Registration InstallationApplication Dimension a Dimension B Dimension C Mounting LocationInstallation of the Lamp Modules Rev E, 06/05/07 Raceway Installation of the Power Junction ModulePreparation of the WIRE/RACEWAY Cover Installation of Main Support Into AIR Handling Duct Lamp Installation Electrical Connection of the SystemRev E, 06/05/07 Rev E, 06/05/07 Mercury Notice Operation Troubleshooting and ServiceBroken Lamp Clean-up Cleaning the Lamps Replacing the Lamp AnnuallyRev E, 06/05/07 661 257-4698 fax Equipment WarrantyPureuvc