Xtant 1.1 owner manual Troubleshooting, Gain Control Adjustment

Page 5

Xtant1.1i Amplifier Owner’s Manual

GAIN CONTROL ADJUSTMENT

1.Turn the Gain control all the way down (counter-clockwise)

2.Set the volume control of the source unit to approximately 23 of its maximum output

3.Turn the balance control of the source unit to its center position

4.Leave the tone (bass/treble) controls at their usual position

5.Play a CD or tape track with wide dynamic range

6.To locate the optimum input sensitivity setting, turn the Gain control clock- wise until audible distortion starts to develop. Turn the sensitivity control counter- clockwise slightly to minimize the distortion.

7.If you often switch between sources (CD, tape, radio, etc.) you will need further adjustment since radio output level differs from that of CD or tape. In this case, you need to locate a balanced sensitivity setting which is best for the output level of your sources.

TROUBLESHOOTING

SYMPTOM: No power

SOLUTION: Check connections to the amplifier’s Ground, B+ & Remote terminals. Check con- nection at “+” terminal of the battery. Check the remote turn-on terminal. Ensure it receives power when the source is turned on (or when the switch is turned on). Refer to the Installation Section. Check the power line fuse: if fuse is blown, replace it; if fuse continues to blow, check the power wire and also the amplifier for a short. If the short is in the power wire, fix it; if the short is in the amplifier itself, see your Xtant dealer.

Check the voltage at the amplifier, and the remote ON/OFF lead. The voltage should measure between 11 V - 15 V. If the measurement is beyond this range, have the source unit checked out by an authorized dealer.

SYMPTOM: Power without sound with red power indicator on

SOLUTION: Turn the amplifier off, and Check all input & output signal cables and connections. Check the speakers for short with a VOM (volt meter) or by connecting them to another audio system. After making sure everything is normal, turn the amplifier on again.

SYMPTOM: No sound

SOLUTION: Check balance control. Check speaker connections. Check signal input connection.

SYMPTOM: Very low sound from both radio & other source

SOLUTION: Check your radio’s fader control. Check the amplifier’s Input Sensitivity Level.

SYMPTOM: Frequent automatic amplifier shut down

SOLUTION: This indicates that the amplifier is operating continually at an exceedingly high

internal temperature. High operating temperature caused by inadequate ventilation: Refer to the sub-section titled LOCATION for better amplifier location.

High operating temperature caused by an excessively low impedance load, say below 2 ohms stereo: Check for bad speakers and/or electronic crossover, proper passive crossover compo- nents; if difficulty persists, please consult your local authorized Xtant retailer.

High operating temperature can be caused by an incorrect input sensitivity level: refer to sub- section titled GAIN CONTROL ADJUSTMENTS for correct setting.

SYMPTOM: “Motorboating”: The amplifier power indicator going off repeatedly when the audio system is on

SOLUTION: Check the amplifier’s connection to the battery. Check battery voltage. If low, recharge or replace battery. Check all ground connections.

xtant.com

9

Image 5
Contents Xtant1.1i Amplifier Specifications Installing Your Xtant AmplifierWelcome to Xtant Français Español DeutschOptional Performance Enhancements Performance FeaturesConnections & Controls Installation SafeguardsGain Control Adjustment TroubleshootingBienvenue Chez Xtant Installation DE L’AMPLIFICATEUR XtantCaractéristiques DE Fonctionnement Mesures DE Protection EN CAS DE Difficulté Réglage DE LA Commande DE GainNota VEA LAS Especificaciones EN LA Página 3 DE Este Manual Bienvenido a XtantInstalación DEL Amplificador Xtant Mejoramientos Opcionales DE Desempeño Características DE DesempeñoProtección Ajuste DEL Control DE Ganancia Detección Y Reparación DE AveríasNstallieren DES XTANT-VERSTÄRKERS Willkommen BEI XtantAnschlüsse UND Bedienelemente LeistungsmerkmaleOptionale Leistungsverstärkung Schutzeinrichtungen Einstellung DER Verstärkungsregelung FehlersucheXtant Four Year Limited Warranty