Mitel 3300 manual Release 103, R2 Card Specifications, Administration of R2 Card Software

Page 111

 

 

 

 

 

Specifications

 

R2 Card Specifications

 

 

 

 

 

 

 

 

 

 

Card type:

DSU with network interface assemblies

 

 

 

 

 

Protocols supported:

The R2 card supports the CCITT Blue Book, Volume VI, Fascicle VI.4,

 

 

Specifications of Signaling System R2, Recommendations Q.440 to Q.490

 

 

(with the exception of Echo Suppression (Q.479), Test Calls (Q.490) and

 

 

international signals).

 

 

 

 

Tone generation

Low Tone

High Tone

 

 

 

-1 to -12 dBm

-1 to -12 dBm

 

 

 

 

 

 

 

 

Tone detection

Normal

Low

 

High

 

sensitivity

-35 dBm

-15 dBm

-50 dBm

 

 

 

 

 

 

R2 signaling

Tone

Backward (Groups

Forward (Groups I & II)

 

frequencies (in Hz)

 

A&B)

 

 

 

 

 

 

 

 

 

15

540

+ 660

1980 + 1860

 

 

14

540

+ 780

1980 + 1740

 

 

13

540

+ 900

1980 + 1620

 

 

12

540

+ 1020

1980 + 1500

 

 

11

540

+ 1140

1980 + 1380

 

 

10

660

+ 780

1860 + 1740

 

 

9

660

+ 900

1860 + 1620

 

 

8

660

+ 1020

1860 + 1500

 

 

7

660

+ 1140

1860 + 1380

 

 

6

780

+ 900

1740 + 1620

 

 

5

780

+ 1020

1740 + 1500

 

 

4

780

+ 1140

1740 + 1380

 

 

3

900

+ 1020

1620 + 1500

 

 

2

900

+ 1140

1620 + 1380

 

 

1

1020 + 1140

1500 + 1380

 

 

 

 

 

 

Administration of R2 Card Software

The IMAT (ISDN Maintenance and Administration Tool) application is used to perform operation and maintenance functions on the R2 card. You can use IMAT to download R2 card software for backup and upgrade purposes and to install or restore the database.

IMAT runs on an independent computer with a Windows 95, 98, or 2000 Professional operating system and is connected to the R2 card through a serial link. The IMAT computer accesses the R2 card either through a direct connection on-site or remotely through a modem.

To install the IMAT application, see the README.TXT file on the R2 card software CD-ROM. For more information on IMAT, refer to Using the ISDN Maintenance and Administration Tool (IMAT).

Software Upgrades

Use IMAT to upgrade the R2 card software and to install or restore the database. For more information on upgrading R2 card software, refer to the IMAT online Help.

Details of how to perform software upgrades are given in Upgrading or Re-installing R2 Software.

Release 3.3

103

Image 111
Contents Hardware User Guide Page Before You Begin SpecificationsTable of Contents SpecificationsRelease ICP Hardware User GuideInstalling 111 Installing146 Install Upgrades and FRUs TroubleshootingProgramming Viii Before You Begin ICP Hardware User Guide ICP Release Printing the Hardware User GuideWhats New in this Release? Before You BeginICP Hardware User Guide ICP Release DisclaimerTrademarks CopyrightSafety Instructions ICP Hardware User Guide Specifications ICP Hardware User Guide Dtmf Output Signaling as specified by EIA/TIA 464-C Technical Information Technical CharacteristicsSignaling and Supervisory Tones Dtmf SignalingFeature Time-Out Period Description Line and Trunk Support Characteristics NACompliance Transmission CharacteristicsRequirements Specifications Loss and Level MatricesImplementation Country Requirement DocumentPort Abbreviation Brazil Loss Plan Matrix Specifications Australia Loss Plan MatrixICP Hardware User Guide France Loss Plan Matrix Italy Loss Plan Matrix GermanyNetherlands Loss Plan Matrix Latin AmericaNorth America Loss Plan Matrix Specifications New Zealand Loss Plan MatrixSpain Loss Plan Matrix ICP Hardware User Guide Portugal Loss Plan MatrixTone Frequency Cadence s Tone PlansUnited Kingdom Australia Tone PlanTone Output Level IONS Brazil Tone PlanSpecifications ICP Hardware User Guide France Tone Plan Special Busy Special Ringback Transfer Dial Voice Mail Italy Tone Output Levels IONS Latin America Tone Frequency Hz Cadence s NetherlandsNew Zealand Tone Plan Tone Plan Frequency Cadence s IACO IACOs North AmericaIONS IOPSPortugal Spain Transfer Dial Voice Mail IACO E2T Compression Conference/ACD Silent Monitor and compression licences Music on Hold and compression Voice mail and compressionInternal Components Controller Mitel Networks 3300 100 Controller ComponentsFront Panel Rear PanelConfigurations User System without Compression User System with 32 Compression Channels User System with 30 Voice Mail Ports Specifications Front Panel Configurations User System without Compression User System with 30 Voice Mail Ports User System with 32 Compression Channels Specifications User System with 64 Compression Channels Specifications User System without Compression User System with 32 Compression Channels User System with 64 Compression Channels Controller Power Mitel Networks 3300 Controller DimensionsController Environment PCB Printed Circuit Board Interfaces ICP Hardware User Guide Output PowerConnector Type Quantity Signals Comments Function Controller PCB InterfacesMitel Networks 3300 Universal NSU Components Network Services UnitsE1/MF-R2 Mode/Connector DIP Switch Settings Universal NSU DIP Switch SettingsHybrid Port DIP Switch Settings PRI/T1 Mode Connector DIP Switch Settings3300 R2 NSU Protocols Mitel Networks 3300 R2 NSU ComponentsMitel Networks 3300 BRI NSU Components 3300 R2 NSU DIP Switch SettingsMitel Networks 3300 NSU Dimensions NSU EnvironmentBRI NSU Protocols ICP Hardware User Guide Operational Environment NSU PowerPower Supply NSU Pin AllocationsRS-232 Maintenance Connector Allocation BRI Connector AllocationSignal Name RJ-45 Connector Pin Mitel Networks 3300 ASU Components ASU and Universal ASU Environment ASU and Universal ASU DimensionsPair Connector Pin Allocations ASU and Universal ASU PowerPower Supply Input Specifications CIM Connector Pin AllocationsPaging Connector Pin Assignments Universal ASU only ONS Line SpecificationsSpecifications Pair Connector Pin Allocations Music on Hold Connector Pin Allocations Universal ASU onlyTransmission Parameters for LA Parameters for EU ONS Transmission Parameters ASUONS DC Supervision Parameters ASU Transmission Parameters for NA Parameters for UKONS Message Waiting Parameters ASU LS Trunk SpecificationsLS Trunk Features 3300 Universal ASU only ONS Ringing Parameters ASUTrunk Functions Parameters for NA/LA Parameters for UK/EU Music On Hold 3300 Universal ASU onlyLS Trunk Parameters 3300 Universal ASU ASU Variant LS ProtocolPaging 3300 Universal ASU only System Fail Transfer 3300 Universal ASU onlyLS Trunk ONS Port Peripheral Node Peripheral Unit Components Specifications Peripheral Unit Environment Peripheral Unit DimensionsPeripheral Unit Power Equipment Power RequirementsPeripheral Unit Cards LS/GS Trunk Card Trunk Card Operation SN-1 and SN-2 Switch SettingsFiber Interface Module Specifications 9400-300-301-NA DID/Loop Tie Trunk Card ICP Hardware User Guide OperationDNI Line Card ONS Line Card Feature Germany China Intl ONS Line Card Variant SpecificationsOPS Line Card ONS CLASS/CLIP Line CardMessage-Waiting Switch Types OPS Line Card SpecificationsSetting Description Dtmf Receiver Card Dtmf Receiver Card SpecificationsSpecifications Release Digital Service Unit Digital Service Unit Components Digital Service Unit Environment Digital Service Unit DimensionsEquipment Digital Service Unit PowerCard Type Digital Service Unit CardsCept Formatter Card Specification Cept Formatter CardConference Card Cept Interface Assembly Connector Shield GroundingDS1/T1 Formatter II Card Specifications OperationCard Specifications DS1 Formatter CardLink Basic Rate Interface BRI CardBRI Cable Pinout for 6-port Card BRI Cable Pinout for 15-port CardPair Pin Color Code BRI Port BK/GR Programmable Data Inversion NA only Dual Port T1 PRI Universal T1 Card FeaturesDual Port E1 PRI Universal E1 Card Features Administration of PRI Card SoftwareMultiple Isdn Variants and Configurations Software UpgradesR2 signaling Line SignalingR2 Card Event Token Description Register SignalingSignal direction Event Function Group Event GroupEvent Group a Release 101Physical Specifications 102Event Group B R2 Card Specifications Administration of R2 Card SoftwareRelease 103 Telephone Power Options Telephone Power Sources Power Dongle Cisco compliant104 Release 105 PowerDsine In-line Power UnitSpecifications Cisco Switches PowerDsine 24PT In-line Power Unit Components106 ICP Hardware User Guide Front PanelPowerDsine 24PT In-Line Power Unit Interfaces PowerDsine 24PT In-Line Power Unit DimensionsPowerDsine 24PT In-Line Power Unit Power Power Supply PD-PH-6024/AC/48ICP Hardware User Guide Ethernet Interface Serial Port Interface108 Installing ICP Hardware User Guide 110 Release 111 Installation SiteInstalling Required ComponentsApplication Information and ServicesParts and Equipment 112Power Uninterruptible Power SupplyRelease 113 114 System Installation OverviewInstallation Planner System Administration ToolRelease 115 116 Parameter Name User / 250 User Controllers CapacityHardware Capacity Release 117ICP Hardware User Guide Hardware Capacity 118Parameter Name Number Release 119 Install the 3300 Controller 120250 / 700 User Controller Install the Hard Drive Release 121User Controller 122 Install the System ID Module250 / 700 User Controller User ControllerInstall DSP Modules Configure the ControllerRelease 123 124 Internal Dhcp Server default settings shipped enabledRelease 125 Set the 3300 Controller IP AddressInstall the 3300 Configuration Tool Hardware Requirements Install the 3300 Configuration Tool126 Click Local Users and Groups Install and Configure the Java Plug-InProgram FTP User Account and Password WindowsClick Local Users and Groups Click Groups Configure IIS 5 SettingsAssign Domain Account Click New UserCopy the identitydb.obj file Install the 3300 Universal NSUSelect the Default Web Site Select Action Properties Select Add and Enter default.aspInstall for PRI/Q.SIG Install Direct Connect Device DriverDriver for Windows 95 and Windows Release 131 Driver for WindowsCreate a Dial-up Network Connection Dial-up Connection for Windows 95 or Windows132 Install the 3300 R2 NSU Dial-up Connection for WindowsRelease 133 Connect the 3300 R2 NSU to the 3300 Controller Install the 3300 BRI NSUConnections Connect the computer to the 3300 R2 NSURelease 135 Setting Up the Maintenance PCInstall the 3300 Universal ASU NSU Chaining136 Install the 3300 ASUSlot Number Card Type Unpack, Position, and Ground the Peripheral UnitPeripheral Unit Card Layout Release 137138 Connect Fiber Cable to the Peripheral UnitRelease 139 Peripheral Unit Grounding140 Power ConverterRelease 141 Install Peripheral Interface CardsCable the Unit to the MDF About Peripheral Interface CablingPeripheral Wiring Backplane 142 Peripheral Interface Cabling Tables Usoc Connector Pin DesignationsCable Connectors Usoc Connector Pin Designations144 Release 145 Card Connections to Cross-Connect FieldCard Slot Card Slot 1 Connections To Cross-Connect Field146 Card Slot 2 Connections To Cross-Connect FieldRelease 147 Card Slot 3 Connections To Cross-Connect Field148 Card Slot 4 Connections To Cross-Connect FieldBackplane Code Trunk Plugs Release 149150 Card Slot 5 Connections To Cross-Connect FieldRelease 151 Card Slot 6 Connections To Cross-Connect Field152 Card Slot 7 Connections To Cross-Connect FieldRelease 153 Card Slot 8 Connections To Cross-Connect Field154 Card Slot 9 Connections To Cross-Connect FieldRelease 155 Card Slot 10 Connections To Cross-Connect Field156 Card Slot 11 Connections To Cross-Connect FieldRelease 157 Card Slot 12 Connections To Cross-Connect Field158 Install the Peripheral Slot FIM CarrierRelease 159 Install the Superset HUB160 Unpack, Position, and Ground the DSURelease 161 DSU Card LayoutConnect Fiber Cable to the DSU DSU Card LayoutInstall DSU Cards Interface Assembly162 DS1 Interface Assembly and Cabling Cept Interface Assembly and CablingRelease 163 Install Wireless Devices Install Symbol NetVision MiNET Phone Administrator Tool164 Release 165 Install 3300 ICP as a Stand-alone IP GatewayInstall 3300 ICP as a Stand-alone Voice Mail Install the 3300 In-Line Power Unit166 Shelf Mounting Powering UpPower-Up LED Sequence Rack MountingData In Ports Connecting Cables to the In-Line Power UnitConnecting Cables to End Devices Data & Power Out PortsInstall the 3300 In-Line Power Adapter Install 3300 Power Dongle Cisco compliantRelease 169 170 Pre-Release 3.2 IP PhonesRelease 171 Mixed Release 3.1 and 3.2 NetworkICP Hardware User Guide 172 Install Upgrades and FRUs ICP Hardware User Guide 174 Release 175 Controller Upgrade OptionsInstall Upgrades and FRUs Hardware176 User System Add Voice Mail PortsRelease 177 User System Add 32 Compression Channels178 User System Add 32 Compression Channels and Voice Mail PortsRelease 179 180 Release 181 182 Release 183 User System Add 64 Compression Channels184 Release 185 User System Add 64 Compression Channels and Voice Mail Ports186 User to 700 User System No Compression ChannelsRelease 187 188 User to 700 User System 32 Compression ChannelsRelease 189 User to 700 User System 64 Compression Channels190 User System Add 32 Compression ChannelsRelease 191 192 User System Add 64 Compression ChannelsRelease 193 194 SX-2000 Light to 3300 ICPRelease 195 Software Software Upgrade Procedure 3.2 toSX-2000 Micro Light to 3300 ICP ICP to 3300 ICP196 ICP Hardware User Guide Mitel Options PasswordDatabase backup Java Plug-InInstall Upgrades and FRUs Before you begin You also needRelease 197 ICP Hardware User Guide Upgrade Procedure Overview Backing up the database198 Release 199 Click System Administration ToolClick Maintenance and Diagnostics, then click Back-up Installing 3.3 software upgradingRebooting Setting your purchased Mitel options200 Release 201 Restoring the databaseUpgrading IP sets and forcing lease renewals Upgrade SX-2000 Light to 3300 ICP SoftwarePerforming maintenance checks Resetting to initialize Voice MailRelease 203 Upgrade SX-2000 Micro Light to 3300 ICP Software204 Upgrade 3200 ICP to 3300 ICP SoftwareRelease 205 206 Release 207 208 Field Replaceable UnitsController FRUs Replace the CoverDual FIM Module DSP or Echo Canceller Module Release 209210 Hard DriveSystem ID Module User and 700 User ControllersRelease 211 212 ICP Hardware User Guide User ControllerRemove a Circuit Card Peripheral Node FRUsICP Hardware User Guide Install a Circuit Card Install a Power Converter214 Release 215 216 ICP Hardware User Guide Install a Cooling FanInstall an Electronic Filter for Cooling Fan Install a Fiber Interface Module FIMRelease 217 Install a Peripheral Switch Controller Card PSCInstall a Dual 10Base-T Interface Assembly Install a FIMDSU FRUs Power Down the DSU Power Up the DSU218 Install a BRI Interface Assembly Installation SequenceRelease 219 220 ICP Hardware User Guide Install a BRI CardInstall a Cept or DS1 Formatter II Card Testing the CardRelease 221 222 Install a PRI CardInstall for PRI Qsig Connect PRI Card to the NetworkRelease 223 Install a Peripheral Resource Card224 Install a FIMConfigure for Line Side/Trunk Side Termination DSU R2 Card R2 Installation OverviewRelease 225 ICP Hardware User Guide Install the R2 Card Connect the R2 card to the Pstn network226 Pin Function Install Upgrades and FRUs RJ-45 Conncector Pin FunctionsField Replaceable Units Hardware Release 227228 Install Upgrades and FRUs Hardware Release 229Software Options 230 Programming ICP Hardware User Guide 232 Overview of Programming Use ImatRelease 233 234 From the File menu, select Connect to Remote SiteTroubleshooting ICP Hardware User Guide 236 Release 237 Alarms LEDsTroubleshoot the 3300 Controller Fiber Interface Module LEDsTroubleshoot the 3300 Universal NSU System Hardware ProfileLED State Meaning Message Link Controlled Card statusRelease 239 CIM LED State Description240 Troubleshoot the 3300 R2 NSUICP Hardware User Guide Fiber Interface Module LEDs R2 NSU Link StatusTroubleshoot the 3300 Universal ASU Troubleshoot the 3300 BRI NSULS Trunk Circuit LEDs Troubleshoot the 3300 In-Line Power UnitLEDs Power Status Indications Troubleshoot the 3300 ASURelease 243 TroubleshootingMain Power Status Indications AC LED Green Unit Status Indications Alarm LED Orange244 Symptom ResolutionOn one port is lit Release 245FIM LED State Meaning Peripheral UnitTroubleshoot Fiber Interface Module 246Release 247 248 Release 249 Troubleshoot LS/GS Trunk CardICP Hardware User Guide 250 Troubleshoot the ONS Line Card Troubleshoot the ONS CLASS/CLIP CardRelease 251 252 Release 253 Troubleshoot the BRI Card254 Troubleshoot the CEPT/DS1 Formatter CardTroubleshoot the Conference Card ICP Hardware User Guide BRI LEDsRelease 255 Troubleshoot the PRI CardFaceplate LEDs PRI Card Link StatusTroubleshoot the R2 Card R2 Card Link Status256 Troubleshooting OtherRelease 257
Related manuals
Manual 78 pages 35.43 Kb Manual 26 pages 48.17 Kb Manual 41 pages 28.55 Kb Manual 41 pages 22.9 Kb Manual 22 pages 2.96 Kb Manual 35 pages 43.54 Kb

3300 specifications

The Mitel 3300 is a robust IP-PBX (Private Branch Exchange) designed to cater to the communication needs of businesses of varying sizes. Renowned for its versatility and extensive features, the Mitel 3300 supports both traditional telephony and modern IP-based communications, making it an ideal choice for organizations transitioning into a unified communications environment.

One of the standout features of the Mitel 3300 is its comprehensive set of communication tools. The system supports voice, video, and data services, allowing users to interact through various formats. With an emphasis on mobility, the Mitel 3300 includes mobile applications that enable staff to connect from anywhere, ensuring seamless communication regardless of location.

The Mitel 3300 system is powered by the Mitel Communications Director (MCD) software, which provides central management and control functions. This software is designed to simplify the administration of the phone system, allowing IT teams to manage users, configure features, and monitor system performance through a user-friendly web interface. The platform also supports a wide range of endpoints, including desktop phones, softphones, and mobile clients, ensuring compatibility with existing infrastructure.

Another key characteristic of the Mitel 3300 is its scalability. The system can support small businesses with just a few extensions or large enterprises with thousands of users across multiple sites. This flexibility allows organizations to expand their communication capabilities as they grow, without facing the need for a complete system overhaul.

The Mitel 3300 is built with advanced technologies in mind. Features such as voice-over-IP (VoIP) capabilities enable high-quality audio calls over the internet, reducing costs and improving connectivity. Additionally, the platform supports Unified Communications and Collaboration (UCC) tools, allowing for integrated messaging, presence management, and video conferencing, which further enhance team interactions.

Security is another priority for the Mitel 3300, incorporating features such as encryption and secure access protocols to safeguard communications and sensitive information. This focus on security helps ensure that organizations can rely on the system to maintain privacy and compliance with regulations.

In conclusion, the Mitel 3300 stands out in the realm of business communications with its versatile feature set, scalability, and integration of modern technologies. Its ability to adapt to the evolving needs of businesses, combined with strong security measures, positions it as a reliable solution for organizations looking to enhance their communication infrastructures.