Metrologic Instruments MLPN 2178 manual Pin Function

Page 50

Version “17” Pin Assignments for Keyboard Wedge, RS-232 and Light Pen Emulation

The version “17” scanner head cable is terminated with a male 25-pin D-type connector. To connect the scanner to the PC, may require a communication cable and a transformer. The communication cable is terminated to two 5-pin DIN connectors that will directly connect to an IBM PC XT or AT compatible computer and keyboard. For the scanner to connect to an IBM PS/2 computer and keyboard, an adaptor kit with 6-pin mini-DIN connectors is provided when requested.

The version “17” scanner is designed to be used as a keyboard wedge. However, with the appropriate communication cable, the scanner will also provide RS-232 or light pen emulation interface. When configuring the scanner for one interface versus another, change all necessary parameters for that particular interface. For instance, to configure the scanner for keyboard wedge emulation, recall defaults, select the PC type, keyboard country type and intercharacter delay. For further information, refer to the ScanSelect™ Scanner Programming Guide or ScanSet™ Scanner Configuration Guide.

The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.

Pin

Function

Pin

Function

1

AC Shield Ground

14

Power Ground 1

2

RS-232 Receive Input

15

Light Pen Source

3

RS-232 Transmit Output

16

Light Pen Data

4

CTS Input

17

PC Data

5

RTS Output

18

PC Clock

6

Reserved

19

Power (11 - 30 volts) DC

7

Signal Ground

20

DTR Input

8 - 10

Reserved

21

Keyboard Clock

11

PC +5 Volts DC

22

Keyboard Data

12

Ground

23 - 24

Reserved

13

Earth Ground

25

Power Ground 2

46

Image 50
Contents Installation and User’s Guide Metrologic INSTRUMENTS, INCLocations USA Corporate Headquarters EuropeTable of Contents Appendix C Appendix aAppendix B Appendix DIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Feature CloningVersion 11 IBM 46XX Scanner Configuring the Scanner Configuring the IBM IBM 4684 and 4694 SystemsScanner Installation to a PC Keyboard Port PC TypePage PC Application Note Installation of the MS700 Series Stand Attaching the Scanner to the Stand MS700i and MS720i Series Features Scanner performs a good read of a bar codeVisual Indicators No Red or Green LEDSignaux optiques Ni la diode rouge, ni la diode verte nest alluméeOptische Anzeigen Weder rote noch grüne LeuchtdiodenanzeigeSegnali ottici Né il diodo luminoso rosso né quello verde sono accesiVolume Settings Labels InfraRed IR Object Sensor Symbol Orientation Active Scan Region for the MS700i and MS715i Scanner Active Scan Region for the MS720i Scanner Page Horizontal Scan Width vs. Distance for the MS720i Scanner Depth of Field for the MS700i and MS715i Scanner Mil /1000 Code TypeCode Density Page Depth of Field for the MS720i Scanner Code Type Minimum Small Code Density Element Mil /1000Page Scanner Version Identifier Communication Protocols MaintenanceApplications and Protocols Mechanical SpecificationsAppendix a ElectricalOperational EnvironmentalDefault Settings Appendix BSweda Three Beeps on Timeout No Beeps on IR Timeout Baud Rate Parallel Light 46XX Parallel Light Pen 46XX 232 Appendix C Pin FunctionVersion 2 Pin Assignments for Parallel Communication EOTVersion 26 Pin Assignments for Multi-drop RS-422 Versions 11 and 24 Pin Assignments for RS-485 Pin Function Warranty and Disclaimer Limited Warranty Appendix DDisclaimer Appendix E RemarqueAnmerkung Appendix F PatentsVolume Control Card Page Index LEDLaserklasse UL/CSA/TUV