Metrologic Instruments MLPN 2178 manual Versions 11 and 24 Pin Assignments for RS-485

Page 49

Versions “11” and “24” Pin Assignments for RS-485

The version “11” and “24” scanners head cables are terminated with a male 25-pin D-type connector. To connect the scanner to the host device, may require a communication cable. The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device. This item can be ordered at the same time scanner is purchased.

The version “11” and “24” scanners are designed to be used primarily with IBM® 46XX series of electronic cash registers. It can also be configured to communicate using the full RS-232 and OCIA protocol.

The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.

Pin

Function

1

AC Shield Ground

2

RS-232 Receive Input

3

RS-232 Transmit Output

4

CTS Input

5

RTS Output

6

Reserved

7

Signal Ground

8 - 12

Reserved

13

Earth Ground

14

Power Ground 1

15

468X -B

16

468X +A

17

OCIA Clock In Return

18

OCIA Clock In

19

Power (11 - 30 volts) DC

20

DTR Input

21

OCIA Clock Out

22

OCIA Clock Out Return

23

OCIA RDATA

24

OCIA RDATA Return

25

Power Ground 2

45

Image 49
Contents Metrologic INSTRUMENTS, INC Installation and User’s GuideUSA Corporate Headquarters Europe LocationsTable of Contents Appendix B Appendix aAppendix C Appendix DIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Cloning FeatureVersion 11 IBM 46XX Scanner Configuring the Scanner IBM 4684 and 4694 Systems Configuring the IBMPC Type Scanner Installation to a PC Keyboard PortPage PC Application Note Installation of the MS700 Series Stand Attaching the Scanner to the Stand Scanner performs a good read of a bar code MS700i and MS720i Series FeaturesNo Red or Green LED Visual IndicatorsNi la diode rouge, ni la diode verte nest allumée Signaux optiquesWeder rote noch grüne Leuchtdiodenanzeige Optische AnzeigenNé il diodo luminoso rosso né quello verde sono accesi Segnali otticiVolume Settings Labels InfraRed IR Object Sensor Symbol Orientation Active Scan Region for the MS700i and MS715i Scanner Active Scan Region for the MS720i Scanner Page Horizontal Scan Width vs. Distance for the MS720i Scanner Depth of Field for the MS700i and MS715i Scanner Code Density Code TypeMil /1000 Page Depth of Field for the MS720i Scanner Element Mil /1000 Code Type Minimum Small Code DensityPage Applications and Protocols MaintenanceScanner Version Identifier Communication Protocols Appendix a SpecificationsMechanical ElectricalEnvironmental OperationalAppendix B Default SettingsSweda Three Beeps on Timeout No Beeps on IR Timeout Baud Rate Parallel Light 46XX Parallel Light Pen 46XX 232 Pin Function Appendix CEOT Version 2 Pin Assignments for Parallel CommunicationVersion 26 Pin Assignments for Multi-drop RS-422 Versions 11 and 24 Pin Assignments for RS-485 Pin Function Appendix D Warranty and Disclaimer Limited WarrantyDisclaimer Remarque Appendix EAnmerkung Patents Appendix FVolume Control Card Page LED IndexLaserklasse UL/CSA/TUV