Configuration of the Scanner to the Host System

The scanner is shipped from the factory programmed to a set of default conditions. These default conditions are in the Default Settings section of this guide pages 36-41 and in the ScanSelect™ Scanner Programming Guide. The default settings in the ScanSelect guide have an asterisk that appears before the brief definition next to the bar code.

For the scanner to properly communicate with the host system, it needs to be programmed to meet the specific scanning needs. Since each host system is unique, configure the scanner to match the host system requirements. Configure the scanner by entering program mode and scanning the appropriate bar codes that appear in the ScanSelect Scanner Programming Guide. (When using ScanSet™, refer to the ScanSet documentation for information on how to configure the scanner.)

1.Connect the scanner to the host system (Refer to the Scanner Connections to the Host section in this guide).

2.Enter program mode by scanning the ENTER/EXIT program mode bar code as the first bar code after a power up cycle. (The unit will beep three times)

3.Scan the appropriate bar code(s) that appear in the ScanSelect Scanner Programming Guide. (Reveal only one bar code to the scanner each time. With your hand, cover the bar code that is not to be scanned.)

4.Exit program mode by scanning the ENTER/EXIT program mode bar code again. (The new options will be saved and the scanner is ready for normal operation.)

Note: Non-RS-232 interfaces chosen in Section B of the ScanSelect Programming Guide do not match the default settings loaded when the same interface is selected with ScanSet.

4

Image 8
Contents Installation and User’s Guide Metrologic INSTRUMENTS, INCLocations USA Corporate Headquarters EuropeTable of Contents Appendix a Appendix BAppendix C Appendix DIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Feature CloningVersion 11 IBM 46XX Scanner Configuring the Scanner Configuring the IBM IBM 4684 and 4694 SystemsScanner Installation to a PC Keyboard Port PC TypePage PC Application Note Installation of the MS700 Series Stand Attaching the Scanner to the Stand MS700i and MS720i Series Features Scanner performs a good read of a bar codeVisual Indicators No Red or Green LEDSignaux optiques Ni la diode rouge, ni la diode verte nest alluméeOptische Anzeigen Weder rote noch grüne LeuchtdiodenanzeigeSegnali ottici Né il diodo luminoso rosso né quello verde sono accesiVolume Settings Labels InfraRed IR Object Sensor Symbol Orientation Active Scan Region for the MS700i and MS715i Scanner Active Scan Region for the MS720i Scanner Page Horizontal Scan Width vs. Distance for the MS720i Scanner Depth of Field for the MS700i and MS715i Scanner Mil /1000 Code TypeCode Density Page Depth of Field for the MS720i Scanner Code Type Minimum Small Code Density Element Mil /1000Page Scanner Version Identifier Communication Protocols MaintenanceApplications and Protocols Specifications Appendix aMechanical ElectricalOperational EnvironmentalDefault Settings Appendix BSweda Three Beeps on Timeout No Beeps on IR Timeout Baud Rate Parallel Light 46XX Parallel Light Pen 46XX 232 Appendix C Pin FunctionVersion 2 Pin Assignments for Parallel Communication EOTVersion 26 Pin Assignments for Multi-drop RS-422 Versions 11 and 24 Pin Assignments for RS-485 Pin Function Warranty and Disclaimer Limited Warranty Appendix DDisclaimer Appendix E RemarqueAnmerkung Appendix F PatentsVolume Control Card Page Index LEDLaserklasse UL/CSA/TUV