connected. The nomenclature on the CIO-SSH16 corresponds to CIO-DAS16 signals.

2.4 ANALOG INPUT BOARD SETUP

The analog input board must be configured for single-ended input. If the board you are using with the CIO-SSH16 supports both 8 channel differential and 16 channel single-ended configurations, set the board to 16 channels single-ended.

You may also need to configure a jumper on the analog input board to supply the sample-hold signal to the CIO-SSH16. The SSH16 must have a SAMPLE / HOLD signal in order to trigger the LF398 sample & hold chips. The LF398s sample the input signal on each channel when the analog input board samples channel 0 and each channels signal is held until the next time channel 0 is sampled.

Refer to the users manual for the analog input board you are using for details regarding configuration of the analog input and the sample / hold signal output.

2.5 GAIN SWITCHES

Each amplifier has a quad DIP switch located nearby. The four switches control the gain of one amplifier. The gain settings are additive so a total of 16 different gains (including 1) are possible.

The gain of a switch is added when the switch is to the left and not added when the switch is to the right.

Figure 1-5. Ganged Gain Switch

4

Image 8
Contents CIO-SSH16 Copyright 2000 Measurement Computing Corp Adding Amplifiers & Sample / Hold Chips This page is blank Introduction Software Installation Hardware Installation Power Cable Signal Cable Power ConnectorAnalog Input Board Setup Gain SwitchesSignal Connection Connector DiagramAnalog Inputs Floating DifferentialDifferential ExamplePage Amplification ArchitectureAnalog Input CIO-SSH16 vs. Programmable Gain A/D Boards Sample & Hold S15 S16 Sample and Hold Timing Diagram Droop RateResolution Calculation Adding Amplifiers Sample / Hold ChipsRange Calculation Time to Sample CalculationSpecifications Analog input sectionSample / hold section Analog Electronics Voltage DividersPage Common Mode Range Differential & Single Ended InputsPage LOW Pass Filters Common MisunderstandingsGround Loops A/D Resolution & Engineering Units Converter # VoltsEngineering Units Current Loop 4-20 mANoise Sources of NoiseSignal Wire Noise Sensor NoiseSmoothing Data For your notes EC Declaration of Conformity