Figure 6-1. Voltage Divider

The object in using a voltage divider is to choose two resistors with the proper proportions relative to the full scale of the analog or digital input and the maximum signal voltage.

Dropping the voltage proportionally is often called attenuation. The formula for attenuation is:

 

The variable Attenuation is the proportional

Attenuation = R1 + R2

difference between the signal voltage max and the

R2

full scale of the analog input.

 

For example, if the signal varies between 0 and 20

2 = 10K + 10K

volts and you wish to measure that with an analog

10K

input with a full scale range of 0 to 10 volts, the

 

Attenuation is 2:1 or just 2.

R1 = (A-1) * R2

For a given attenuation, pick a handy resistor and

 

call it R2, the use this formula to calculate R1.

Digital inputs also make use of voltage dividers, for example, if you wish to measure a digital signal that is at 0 volts when off and 24 volts when on, you cannot connect that directly to the CIO-DAS16 digital inputs. The voltage must be dropped to 5 volts max when on. The Attenuation is 24:5 or 4.8. Use the equation above to find an appropriate R1 if R2 is 1K. Remember that a TTL input is 'on' when the input voltage is greater than 2.5 volts.

17

Image 21
Contents CIO-SSH16 Copyright 2000 Measurement Computing Corp Adding Amplifiers & Sample / Hold Chips This page is blank Software Installation Hardware InstallationIntroduction Power Cable Power Connector Signal CableGain Switches Analog Input Board SetupConnector Diagram Signal ConnectionAnalog Inputs Floating DifferentialExample DifferentialPage Architecture Analog InputAmplification CIO-SSH16 vs. Programmable Gain A/D Boards Sample & Hold S15 S16 Droop Rate Sample and Hold Timing DiagramAdding Amplifiers Sample / Hold Chips Resolution CalculationRange Calculation Time to Sample CalculationAnalog input section SpecificationsSample / hold section Voltage Dividers Analog ElectronicsPage Differential & Single Ended Inputs Common Mode RangePage Common Misunderstandings Ground LoopsLOW Pass Filters Converter # Volts A/D Resolution & Engineering UnitsCurrent Loop 4-20 mA Engineering UnitsSources of Noise NoiseSensor Noise Signal Wire NoiseSmoothing Data For your notes EC Declaration of Conformity