Miranda Camera Co M406-9900-402 Progressive Rgbhv Input MWI-VGA, Analog Audio Input MWI-SA

Page 30

GUIDE TO INSTALLATION AND OPERATION

SCALES:

EBU DIGITAL PPM (IEC-60268-18), NORDIC (IEC-60268-10 TYPE I), BBC/UK

 

PPM(IEC-60268-10 TYPE IIA), EBU PPM (IEC-60268-10 TYPE IIB)

PROGRESSIVE RGBHV INPUT (MWI-VGA)

SIGNAL (2):

Analog RGBHV

RESOLUTION:

From 640 x 480 to 1600 x 1200 NI signals

REFRESH RATE:

Up to 85 Hz

RETURN LOSS:

> 15 dB up to 65 MHz

LEVEL:

0.4 to 1.2 Vp-p

CONNECTOR:

DE-15S (female)

ANALOG AUDIO INPUT (MWI-SA)

SIGNAL (16):

Balanced analog stereo

IMPEDANCE:

20 kΩ balanced, 10 kΩ single ended, 600Ω selectable

PHASE METER:

-1 To +1 (16 steps)

PEAK BALLISTICS:

 

-RISE TIME:

Instantaneous or 10ms

-FALL TIME:

-20dB/1.5s

VU BALLISTIC:

300ms

SCALES:

VU (IEC-60268-17), EBU digital PPM (IEC-60268-18), BBC/UK PPM(IEC-60268-

 

10 type IIa), EBU PPM (IEC-60268-10 type IIb)

MAX LEVEL:

+24dBu

INPUT TRIM:

0 to 30 dB gain 6 dB steps

CONNECTOR (2):

DSUB 50 (female)

DIGITAL AUDIO INPUT (MWI-AES)

SIGNAL (16):

AES3 balanced (AES3-1992/ ANSI S4.40-1992)

IMPEDANCE:

110Ω

PHASE METER:

-1 To +1 (16 steps)

PEAK BALLISTICS:

 

-RISE TIME:

Instantaneous or 10ms

-FALL TIME:

-20dB/1.5s

VU BALLISTIC:

300ms

SCALES:

VU (IEC-60268-17), EBU DIGITAL PPM (IEC-60268-18), BBC/UK PPM(IEC-

 

60268-10 TYPE IIa), EBU PPM (IEC-60268-10 TYPE IIb)

FREQUENCY:

13 & 14 SRC, 1-12 & 15-16 48 kHz

INPUT TRIM:

0 to 30 dB gain 6 dB steps

CONNECTOR:

DSUB 50 (female)

TIME CODE INPUT

 

DESCRIPTION:

LTC input for clock Synchronization

SIGNAL:

SMPTE 12M-1995 (EBU-3259-E)

LEVEL:

100 mVp-p to 10 Vp-p

IMPEDENCE:

13.5kΩ

CONNECTOR:

BNC

REFERENCE INPUT

 

DESCRIPTION:

Reference input for system genlock

SIGNAL:

SMPTE-170M/SMPTE-318M/ITU 624-4/BUT 470-6 or comp. Sync.

CONNECTOR:

BNC

26 Kaleido K2

Image 30
Contents Kaleido-K2 Safety Compliance Information How to contact usElectromagnetic Compatibility Contents Guide to Installation and Operation Features Introduction1 Kaleido-K2 functional block diagram Overview Front PanelRear Panel Installing Kaleido-RCP in a rack using the mounting bracket Mechanical InstallationRack-mount installation Unpacking2 Moving the connector Installation Frame and Electrical InstallationPower supplies FrameModule installation and replacement OperationVentilation Connector panel installation Module card installationPosition Module type Color Code Module description and connection Controller ModuleLTC USBMouse Keyboard Option1.4 Front edge of Controller module 2.1 GPI rear connector panel GPI Module2.4 Installing lexan on the MWA-TBA-G terminal block adapter 3.1 MWI-SA rear connector panel Analog Audio Input Module MWI-SADigital Audio Input Module MWI-AES Composite Analog Video Input Module MWI-CVBS6 Y/C Analog Video Input Module MWI-YC Component Analog Video Input Module MWI-CAVDigital Video SD-SDI Input Module MWI-SDI Analog Progressive Rgbvh Input Module MWI-VGAHD-SDI Video Input Module MWI-HD Output Module MWO-HRMultiple Kaleido-K2 installation Controlling multiple Kaleido-K2s through an ethernet network1 Cascading two Kaleido-K2s RS-422 Multi-drop Cable Example 3 RS-422 Serial ID AssignmentInstallation of Software OperationStartup and preparation to use software Replacing a defective power supply MaintenanceCleaning the air filter Replacing a defective fan1 Replacing the fan Specifications Digital Audio Input MWI-AES Progressive Rgbhv Input MWI-VGAAnalog Audio Input MWI-SA Time Code InputDVI Output Progressive Rgbhv Output 1 MWO-HRProgressive Rgbhv Output 2 MWO-HR Audio Monitoring Output MWO-HREthernet PORTMWA-CPU Remote Control PanelRemote Port MWA-CPU USB PORTMWA-CPU