Pressure Systems 9046 user manual Read Primary Transducer E. U. Data at High Speed Command ’b’

Page 45

Pressure Systems, Inc.

Model 9046 User’s Manual

 

 

5.6 Read Primary Transducer E. U. Data at High Speed (Command ’b’)

Purpose:

Returns the most recent Primary Transducer E. U. data from all channels of the module as fast as possible. Data is returned directly in its native internal (IEEE single-precision float) binary form (i.e., as for format code 7 in other commands). It is used as a faster alternative to the Read High-Precision Data (‘r’) command, since ‘b’ does not have to parse any parameters, nor does it have to transform or encode the internal data into any other format when the response is generated.

 

Command

 

 

"b"

 

 

 

 

 

’b’ is the operation code

 

 

 

 

 

 

 

 

Response

 

 

aaaabbbbcccc..pppp

 

 

 

 

 

 

 

 

 

Note that this response if not in quotes, because it

 

 

 

 

 

is a stream of binary bytes. Each 4-byte datum

 

 

 

 

 

(e.g, aaaa) is a non-human readable big-endian

 

 

 

 

 

value (format 7) representing an IEEE single-

 

 

 

 

 

precision internal float value.

 

 

 

 

 

 

 

Description: Returns primary E.U. data for all of the module’s channels in order highest channel number to lowest channel number. Thus channel #16 will always be the first 4-byte (32- bit binary, big-endian, IEEE floating-point) value (’aaaa’) sent in the response. Any special datum values (e.g., 99999 or 88888) used to indicate out-of-range or erroneous calculations or physical connections are re-scaled to lower values (e.g., 999.99 or 888.88) for this command only.

Example:

Command module to return all its primary transducer E. U. data as fast possible:

"b"

Data from the most recent scan of all the module’s channels are returned in pure binary form, 4- bytes per channel (big endian) of each internal IEEE float:

aaaabbbbcccc .. pppp

Page 39

www.PressureSystems.com

Image 45
Contents Model Ethernet Intelligent Temperature Scanner User’s Manual Page Table of Contents Merchandise Return Procedures Our WarrantyOur Company Technical SupportWebsite and E-Mail Our Firmware Our Publication Disclaimer This page left intentionally blank Introduction GeneralIntroduction Exploded View of Module Physical DescriptionThermocouple Cold Junction Compensation Theory of OperationOpen Circuit Detection Setup InstructionsEquipment Required Network Dialog Box Computer PreparationTCP/IP Properties Dialog Box Cable Connections Module ConnectionPressure Systems, Inc Model 9046 User’s Manual Network Status Screen IP Address AssignmentNetwork Status after connection ConfigureNetwork Options Pulldown Menu Pressure Systems, Inc Model 9046 User’s Manual Set Sensor Type Sensor Type Values Read Sensor Type Thermocouple Reference Temperature AlarmsC05 Read Temperature Units Set Temperature UnitsWrite EU Filter Parameter V0110b ddV00152 U00152 Read EU Filter ParameterCalibration V00100 H0001U00100 W08Pressure Systems, Inc Model 9046 User’s Manual Sensor Type Gain Setting Engineering Va, Vb Units FirmwareDescription of Operation Thermocouple VoltageResistance ThermistorUpdating the Firmware This page intentionally blank Command Quick Reference Command SetPressure Systems, Inc.Model 9046 User’s Manual Summary Information About All Commands Pressure Systems, Inc Model 9046 User’s Manual Pressure Systems, Inc Model 9046 User’s Manual No Operation Command ’A’ Reset Command ’B’ Purpose Read Primary Transducer Volts Command ’V’Vppppf Dddd.. dddd999999 -4.989500 0.005390 V11110Read Primary Transducer A/D Counts Command ’a’ 32767.000000 -32700.000000 10.000000 A11110Aaaabbbbcccc..pppp Read Primary Transducer E. U. Data at High Speed Command ’b’Nuss does not use this command normally. You may execute it Define/Control Autonomous Host Streams Command ’c’ Pressure Systems, Inc Model 9046 User’s Manual Pressure Systems, Inc Model 9046 User’s Manual Pressure Systems, Inc Model 9046 User’s Manual Pressure Systems, Inc Model 9046 User’s Manual Read response 00 1 000F 0 1 7 0 c 00 2 00F0 0 2 7 0 c 00 3 FF00 0 4 7 Pressure Systems, Inc Model 9046 User’s Manual Command ’c’- Sub-command Index 01 Start Streams Example Space Command ’c’- Sub-command Index 02 Stop StreamsExample 02 0 c 03 3 c 01 Command ’c’- Sub-command Index 03 Clear StreamsPressure Systems, Inc Model 9046 User’s Manual Character Command ’c’ Sub-command Index 04 Return Stream InformationFfff 0 20 7 32000 1 7002 200.200.200.1 DescriptionPrefix/Data Groups Enable UTR Temperature/Other EU Data ûC Enable Primary Transducer Temperature/ResistanceEnable UTR Temperature/Other A/D Counts Enable UTR Temperature/Other Voltages05 1 Command c 06 st pro remport ipaddr 06 0 06 0 1Nuss does not normally use this command since it generates This page intentionally left blank Model 9046 Ethernet Interface Cable Appendix a Cable DiagramsModel 9046 Ethernet Interface Cable Headquarters/Factory European Office

9046 specifications

Pressure Systems 9046 is a highly advanced pressure management solution designed to cater to various industrial and commercial applications. Renowned for its robust performance and reliability, this system is engineered to optimize pressure levels in a wide range of environments, ensuring efficiency and safety in operations.

At its core, Pressure Systems 9046 integrates cutting-edge technologies that enhance its functionality and user experience. One of its main features is the Smart Pressure Regulation Technology (SPRT), which utilizes intelligent algorithms to automatically adjust and maintain optimal pressure levels. This ensures that processes run smoothly, minimizing the risk of pressure fluctuations that can lead to equipment damage or operational downtime.

Another standout characteristic of the Pressure Systems 9046 is its modular design. This allows for easy scalability and customization, enabling users to configure the system according to their specific needs. Whether addressing low-pressure applications or high-pressure requirements, the modular setup can adapt and expand, providing flexibility for various industrial settings.

In addition, the system is equipped with advanced monitoring capabilities. With real-time data tracking and reporting, operators can monitor pressure levels, detect anomalies, and analyze trends. This proactive approach to pressure management enhances operational efficiency, reduces costs, and ensures compliance with safety standards.

Durability is another hallmark of Pressure Systems 9046. Built with high-quality materials, it can withstand harsh environmental conditions, including extreme temperatures and corrosive substances. This robust construction not only extends the lifespan of the system but also reduces maintenance needs, offering long-term reliability.

Moreover, Pressure Systems 9046 supports remote monitoring features, allowing users to access system data and control operations from anywhere. This connectivity simplifies management tasks and contributes to a more streamlined workflow, enabling industries to focus on core operations while ensuring pressure systems are performing optimally.

In conclusion, Pressure Systems 9046 stands out due to its innovative technologies, user-friendly design, and exceptional durability. Its combination of smart pressure regulation, modularity, real-time monitoring, and remote access makes it an indispensable tool for various industries looking to enhance their pressure management strategies. As industries continue to evolve, Pressure Systems 9046 is poised to meet the changing demands of the market, ensuring safe and efficient operations for years to come.