Pressure Systems 9016 manual Out of Housing, PC-206 Amplifier/Multiplexer Board, PC-206 Board

Page 6

Pressure Systems, Inc.

9016 Upgrade Instructions

Viton® gasket

Figure 4

9016 Out of Housing

Electronic Circuit Board Replacement

Your 9016 contains two (2) electronic circuit boards that must be removed and replaced for this upgrade.

PC-206 Amplifier/Multiplexer Board

The following procedures should be used for removal of the PC-206 Amplifier/Multiplexer Board. Use the tools and follow the general precautions previously described.

(1)Carefully remove the wiring harness from connector P1 of the PC-206 board. (See Figure 5.)

(2)Remove the two (2) Phillips-head screws securing the PC-206 board to the DH200 transducers. Carefully disconnect the PC-206 board from the DH200s by slowly working the board off; starting at one end and moving down the length of the board. It is important to not break the gold pins when removing the board. Inspect the PC-206 boards for broken pins and remove from DH200 transducers, if neccessary.

Wiring harness

Phillips head screws

Figure 5

PC-206 Board

5www.PressureSystems.com

Image 6
Contents Model Upgrade Instructions Packing List Upgrade Instructions Exploded View of 9016 Scanner Top PlateModule Disassembly Use caution not to slip and scratch the top plateRemove only Perimeter Screws Out of Housing PC-206 Amplifier/Multiplexer BoardPC-206 Board PC-280 Board and Connectors PC-280 Ethernet Microprocessor/A-D BoardPC-280 Board Installing the PC-327 Analog Board Tubing Routing Underneath PC-327 BoardPC-327 Board Installing the PC-322/323 Boards PC-322/323 Boards P6 connectionFinding Pin 1 on a PC BoardFigure 9a Top Plate to P1 Connection on PC-322Side View of 9016 Upgrade Top View of 9016 Upgrade PC-327 Connection and Cable Tie-downNoteFinal Installation Final CheckoutHeadquarters/Factory