POSIFLEX Business Machines Jiva TP/LT - 5815, 16280900030 Application Environment, Ventilation

Page 16

USING THE TOUCH TERMINAL

APPLICATION ENVIRONMENT

It is very important to check the following operational guidelines:

Ventilation

This terminal must NOT be used in an environment with restricted ventilation. There must be at least 25 mm air clearance around any ventilation holes with a free flow of air around the unit at ALL times for the installation.

Operating Environment

The equipment must not be operated or stored in extremes of both temperature and humidity/moisture. (Operating range 5°C to 40°C and up to 80% humidity – non condensing, max. wet bulb 26°C)

UPS Battery (option)

General care:

The UPS battery is consumables beyond product warranty. Please definitely observe the alerts in beginning of this manual. Please always disconnect the battery if the system is to be powered off for more than few days. Reconnect it and turn on the system to recharge the battery for 1 ~ 2 hours every 3 months / every month for temperature lower than / over 30°C. Temperature above 40°C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work. The UPS battery can support basically the data preservation and smooth operation during intermittent or few minutes (3 ~ 8 min. depending on loading and battery condition) power failure.

Battery replacement:

In the preloaded OS for a Jiva system, there is a built in utility Power Manager that will interface the UPS battery monitor status with user. When a health warning popup message appears, please immediately replace the used up UPS battery at power off if the battery is actually connected there but found inoperable by such messages.

Emergency treatment:

The battery is constructed maintenance free and leakproof. However, should any accident happen and the sulfuric acid from the battery spills on skin or clothing, wash immediately with water. If the acid comes in contact with eyes, rinse eyes with large amount of clean water and see a doctor immediately. A larger external battery may be connected to give an extended operation. Please check your dealer about this capability when required.

WARNING:

If there are any signs of over charging or leakage of electrolyte please contact your dealer immediately

Part 16

Image 16
Contents FCC Notes Daily Maintenance Guide Alert to OUR Honorable CustomersIntroduction Front ViewsRear Views Parts IdentificationBottom Views Product Features Standard FeaturesOptional Items Part Disconnecting ALL Cables Opening Cable CoverOpening Stand Assembly Separating Main UnitInstalling UPS Battery Cable PassageWall Mounting Base Mount Upgrade KIT 12 2nd LCD Panel Or Customer Display Side & Rear TOP Mount Upgrade KIT Routing the Cables Preparing the Main Unit 15 2nd LCD PanelConnecting Cables Wireless PrinterDesktop Mounting Operating System Recovery Operating System InstallationUPS Battery option Application EnvironmentVentilation Operating EnvironmentPower ON/OFF Power SupplyPower Status LED Indicator Hardware Power SwitchDisplay Issues Software Support FeaturesAutomatic Power On Control Main LCD DisplayCustomer Display Serial PortsSound Ports FAN ControlTouch Panel Mouse EmulationPosiflex USB Touch Manager RS232 Touch Controller