POSIFLEX Business Machines 16280900030 Power ON/OFF, Power Supply, Power Status LED Indicator

Page 17

Power Supply

The operating voltage range of the power adaptor should cover the local power supply for proper operation. The power cable, the power outlet and any power fusing arrangements must conform to local safety regulations.

Please never do any connection / disconnection when system is still powered on. Please always keep the external power adaptor in a free air circulation.

POWER ON/OFF

There must always be at least 10 seconds waiting before switching on again once the system is powered off successfully.

Power Status LED Indicator

There is an LED under the printed logo that serves for several purposes. The relationship between LED status and other conditions is summarized in following table:

LED Status

System Status

External Power

UPS Battery

Powering Up

Off

Off

Off

Not present

Not possible

Off

Off

Off

Present

Not allowed

Green

Off

On

No influence

Allowed

Blue

On

On

No influence

Not required

Blue/flash

On

Off

Activated

Not required

Green/rapid

On

Off

Running at

Not required

flash

low capacity

 

 

 

Hardware Power Switch

The power switch is at left side of the main unit. This switch turns the system on when slid downward, only when external power is present. The switch will always spring back to its original position when pressure is removed. This button turns the system off when slid downward again during power on status. However, if the system hangs due to any reason such as software resource conflict you may have to utilize the forced power off feature by pressing the switch downward, and holding for within 10 seconds. In case this forced power off fails, please disconnect the UPS battery if installed and the AC power supply for few minutes then reconnect them.

This switch can also be programmed as an ON only switch by the application program so that this switch will always turn the system on when activated, but will not power off the system when depressed again (the forced power off feature will not work in this mode). When using this feature, please

Part 17

Image 17
Contents FCC Notes Alert to OUR Honorable Customers Daily Maintenance GuideFront Views IntroductionBottom Views Parts IdentificationRear Views Standard Features Product FeaturesOptional Items Part Opening Cable Cover Disconnecting ALL CablesSeparating Main Unit Opening Stand AssemblyCable Passage Installing UPS BatteryWall Mounting 12 2nd LCD Panel Or Customer Display Base Mount Upgrade KITRouting the Cables Side & Rear TOP Mount Upgrade KITPreparing the Main Unit 15 2nd LCD PanelDesktop Mounting Wireless PrinterConnecting Cables Operating System Installation Operating System RecoveryApplication Environment UPS Battery optionVentilation Operating EnvironmentPower Supply Power ON/OFFPower Status LED Indicator Hardware Power SwitchSoftware Support Features Display IssuesAutomatic Power On Control Main LCD DisplaySerial Ports Customer DisplaySound Ports FAN ControlMouse Emulation Touch PanelPosiflex USB Touch Manager RS232 Touch Controller