Danish Interpretation Systems | User Manual |
|
|
Technical appendix
Cabling
CAT5
The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors.
It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.
EIA
Pin | Function | Connector #1 | Connector #2 |
|
|
|
|
1 | ORG/WHT | ORG/WHT | |
2 | ORG | ORG | |
3 | +48V | GRN/WHT | GRN/WHT |
4 | 0V | BLU | BLU |
5 | 0V | BLU/WHT | BLU/WHT |
6 | +48V | GRN | GRN |
7 | Outgoing - | BRN/WHT | BRN/WHT |
8 | Outgoing + | BRN | BRN |
Note. If other colour codes are used then the four pairs are connected as follows:
Pair 1: Pin 1 & 2
Pair 2: | Pin 3 & 6 |
Pair 3: | Pin 4 & 5 |
Pair 4: | Pin 7 & 8 |
The phase of the pairs must be correct and the wiring spec. as stated in CAT5 (EIA
Note: CAT6 cables can normally only be terminated in sockets (female) and not in cable plugs. CAT6 should thus only be used for long cable draws terminating in wall outlets or patch panels.
Accessories (not supplied) |
|
Cat 5e Connection Cables (AWG24) |
|
EC | 10 03 12500 |
EC | 10 03 13101 |
EC | 10 03 13201 |
EC | 10 03 13501 |
EC | 10 03 14102 |
EC | 10 03 14202 |
EC | 10 03 14502 |
Set of 1HU - 19” Brackets |
Technical specifications
General
Power consumption | .................................................... | max. 10W |
Temperature to guarantee specified performance | ||
............................. 5 | Deg C. to 40 | Deg C. (35 to 80% humidity) |
Storage temperature |
|
|
.......................... | Deg C. (10 to 80% humidity) | |
Weight | 1 kg |
Dimensions (W x H x D) | 264 x 42 x 128 mm |
Dimensions with 19” brackets | 482,6 x 44 x 128 mm |
Connectors
2 pieces RJ45 | |
4 pieces RJ45 |
Specifications are subject to change without notice.
Manual 01 18 04466 | 13 |
|