Novatel GM-14915118 quick start ASP-163577-01

Page 4

Ref

Connector

Part Number

Mating Connector

Description

4

J301

ASP-163577-01

N/A

Connects to the P1101 connector on the OEM615

 

 

(Samtec)

 

 

 

 

5

P701

53780-1070

51146-1000

Connects to ADIS IMUs

 

 

(Molex)

(Molex)

(NovAtel supplied cable)

6

P601

53780-2070

51146-2000

Connects to HG1700, HG1900, HG1930 and

 

 

(Molex)

(Molex)

STIM300 IMUs (NovAtel supplied cable)

7

P1101

TMM-110-03-G-D

N/A

Connects to the J301 connector on the MIC

(Samtec)

 

 

 

 

Complete the following steps to connect and power your MIC and OEM615.

(ESD) measures are in place, in particular, use a ground strap before exposing or handling any electronic items, including the MIC, receiver and IMU. Take care to prevent damaging or marring painted surfaces, O-rings, sealing surfaces and the IMU.

For more information about ESD practices, see the OEM6 Family Installation and Operation User Manual available from our website at www.novatel.com.

1.Attach the IMU mounting PCB to the IMU.

Ensure all the pins on the header are aligned with the holes on the mating connector.

An IMU mounting PCB is not used with the STIM300 IMU.

2.Mount the IMU and antenna securely to a vehicle.

For the simplest operation, align the Y-axis of the IMU with the forward axis (direction of travel) of the vehicle. Ensure the Z-axis is pointing up.

Ensure that the GNSS antenna and IMU cannot move relative to each other. The distance and relative direction between them must be fixed.

For center of navigation diagrams of the ADIS and STIM300 IMUs, see the SPAN on OEM6 User Manual available from our web site at www.novatel.com.

For center of navigation diagrams of the HG1700, HG1900 and HG1930 IMUs, contact NovAtel Customer Support. See Questions or Comments on page 12 for contact information.

3.Use the standoffs supplied with the MIC to mount the OEM615 receiver in a secure enclosure to reduce environmental exposure and RF interference. See the OEM6 Family Installation and Operation User Manual for information about mounting printed circuit boards.Assemble in accordance with applicable industry standards. Ensure all Electrostatic Discharge

Industrial).

If alternate standoffs are selected, use equivalent parts with a minimum height of 12 mm.The part number for the standoffs included with the MIC is RAF-M21073005AL7 (Irwin

4

Image 4
Contents BOX Contents Additional Equipment RequiredIMU Setups MIC to OEM-IMU-ADIS-16488 OEM Cable KitInstall the MIC in a Stack UP Configuration MICASP-163577-01 Skip to Install the PC Utilities on Install the MIC in a Standalone Configuration  OEM628 RecommendationsPage Install the PC Utilities Establishing a New Receiver ConnectionConfigure the Span System Connectimu CommandsLOG Span Data Operate the Span System AsciiPOST-PROCESS Data Questions or Comments