La Crosse Technology instruction manual Troubleshooting, Specifications for WS-8011UM

Page 12

TROUBLESHOOTING

Problem:

The LCD is faint.

Solution:

Replace the batteries.

Problem:

“OFL” appears in the indoor temperature LCD.

Solution:

1)

Move unit to an area with warmer or cooler surrounding

 

 

temperature.

 

2)

Current surrounding temperatures are outside measuring

 

 

range.

Problem:

No reception of WWVB signal.

Solution:

1)

It may help reception to face the front of the temperature

 

 

clock in the general direction of Ft. Collins, Colorado.

 

2)

Wait overnight for signal.

 

3)

Be sure the temperature clock is at least 6 feet from any

 

 

electrical devices, i.e. TV sets, computers, or other radio

 

 

controlled clocks.

 

4)

Remove batteries for five minutes, reinsert and leave the unit

 

 

alone overnight without pressing buttons.

 

5)

If problems persist contact La Crosse Technology.

Problem:

Hour is incorrect (minute and date are correct).

Solution:

Be sure correct time zone and daylight saving time are selected.

Problem:

“--.-” appears in outdoor temperature LCD

Solution:

1) Check batteries in the remote temperature sensor.

 

If batteries are replaced in remote temperature sensor the

 

temperature clock must be re-started.

 

Remove all batteries, and then follow start up procedure.

Problem:

“OFL” appears in the outdoor temperature LCD

Solution:

1)

Remote temperature is out of range.

 

2)

Check batteries.

 

3)

Interference from an outside source (cordless telephone, etc.)

 

4)

Contact La Crosse Technology.

Note: For any questions not answered, contact La Crosse Technology with the contact information found at the end of this instructional manual.

SPECIFICATIONS FOR WS-8011UM

Temperature:

Measuring range:

32°F to 122°F with 0.2°F resolution (indoor)

 

-21.8°F to 140°F with 0.2°F resolution (outdoor)

 

(0°C to 50°C with 0.1°C resolution)

Checking intervals:

Every 10 seconds indoor, 3 times in 10 minutes

 

for remote temperature.

Power source:

 

Battery type:

Station: 2 x AA, 1.5V (Alkaline)

 

Transmitter: 2 x AA, 1.5V (Alkaline)

Battery life:

Approximately 12 months

Dimensions (L x W x H):

11.4 x 0.98 x 7.5 in (290 x 25 x 190mm)

12

Image 12
Contents WS-8011UM 433 MHz Radio Controlled Temperature Clock Table of Contents Inventory of Contents Quick SET-UP GuideTemperature Clock II Program Mode Time Zone SettingFunction Buttons DST Daylight Saving Time Setting Time SettingLanguage Selection for the Weekday Calendar Setting 12/24-HOUR SettingAlarm Setting the Alarm Selecting F or CACTIVATING/DEACTIVATING the Alarm Suspending AlarmIndoor Temperature Remote TemperatureIV Mounting Foldout Table StandsWall Mounting Remote Temperature Sensor VI Maintenance & CareMounting with Screws Mounting with Adhesive TapeTroubleshooting Specifications for WS-8011UMWarranty Information FCC ID OMO-01RX receiver OMO-01TX transmitter