Printronix SL5000e Rfid PGL Commands Example, SGTIN-64 ~CREATESGTIN-64432 RFWTAG64, Stop Alpha

Page 28

Chapter 2 RFID PGL Commands

Example 2

Same as Example 1, except the EPC number is broken into its component parts. Assume that the SGTIN–64 value has the Header = 2d, Filter Value = 5d, EPC Manager Index = 15383d, Object Class = 703710d or 0xABCDE, and the Serial Number = 0123456d.

~CREATE;SGTIN–64;432

 

RFWTAG;64

 

2;B;*10*

/Header

3;D;*5*

/Filter Value

14;D;*15383*

/EPC Manager Index

20;H;*ABCDE*

/Object Class

25;D;*0000123456*

/Serial Number

STOP

 

END

 

~EXECUTE;SGTIN–64;1

 

~NORMAL

 

Example 3

Same as Example 2, except it uses a dynamic method.

This example also shows how to program another

RFID tag without redefining the data structure of the

SGTIN–64.

~CREATE;SGTIN–64;432

 

RFWTAG;64

 

2;DF1;B

/Header

3;DF2;D

/Filter Value

14;DF3;D

/EPC Manager Index

20;DF4;H

/Object Class

25;DF1;D

/Serial Number

STOP

 

ALPHA

 

AF1;18;10;5;3;3

 

STOP

 

END

 

~EXECUTE;SGTIN–64

 

~DF1;*10*

/Header

~DF2;*5*

/Filter Value

~DF3;*15383*

/EPC Manager Index

~DF4;*ABCDE*

/Object Class

~DF5;*0000123456*

/Serial Number

28

Image 28
Contents Rfid Labeling Reference Manual Printronix Customer Support Center contact information Rfid Labeling Reference Manual Trademark Acknowledgements Table of Contents Table of Contents Rfid Smart Label Application Reference Notes OverviewOverview What To Expect When Running Your Rfid Application Factors Affecting Smart Label PerformanceOverstruck Smart Labels Factors Affecting Smart Label PerformanceSmart Label Characteristics What To Expect When Running Your Rfid ApplicationHow It Works How Printronix Makes It EasyHow Printronix Makes It Easy How To Order More Smart Labels Printronix Professional ServicesWhat We Can Do Contact InformationHardware/Infrastructure Considerations Contact InformationReference Material Useful Industry Web LinksUseful Industry Web Links Smart Label Development Rfid Control Menu Rfid Control MenuCont. from previous Error Handling Rfid Control Menu ItemsTag Write Cnt Rfid Control Menu ItemsPage Admin User Menu Items Admin User Menu ItemsRfid Test This Test Reads a Tag Custom Tag Len Rfid PGL Commands Rfid PGL CommandsLengthIDFnformat LengthDFn IDFnIdir StepRPTn RSTn~CREATESGTIN-64432 RFWTAG64 ExampleStop END ~EXECUTESGTIN-641 ~NORMAL Rfid PGL Commands Example SGTIN-64 ~CREATESGTIN-64432 RFWTAG64Stop Alpha Stop END ~EXECUTESGTIN-64~NORMAL ~EXECUTESGTIN-64 Stop END ~EXECUTESGTIN-64ICNT1500 ~NORMALLength DFn format Format RFRTAGsizeDF n Stop RFTAG64 FormatStop END ~EXECUTESGTIN-64ICNT1500 ~IDF1STEP+1*0* ~IAF1DF2 ~NORMAL Format VERIFYfieldformatDASCIIheaderDVerify ASCIIheader~CREATEVERIFY432NOMOTION RFRTAG64 Stop RFRTAG64 64DF2HEND ~EXECUTEVERIFY1 ~NORMAL ~CREATEREADONLY432 RFRTAG64~EXECUTEREADONLY1500 ~NORMAL ~CREATESIMPLE432NOMOTION RFWTAG64Stop Rfrtag 64 64DF1H END ~EXECUTESIMPLEICNT2000 ~NORMALWrite Tag FormatRfwrite HEXWrite Tag LockRead Tag Format RDIposition,length,formatRDI PositionGet Tag Unique ID Rfid PPI1 CommandsSet Tag Type Rfid PPI1 Commands Format RT x, start, length, hex, retries, motion, reservedLCD StartMotion Host Verification Format HVx,yASCIIPPI1 EPC Programming Examples PPI1 EPC Programming ExamplesTools List Software Migration Tools SMTSoftware Migration Tools SMT Tools List Selecting The Tools Error Messages Control Panel Error Messages Explanation SolutionSelecting The Tools Rfid MAX RetryTroubleshooting TroubleshootingTroubleshooting the Rfid Encoder Symptom Solution Setup GuideTroubleshooting Troubleshooting Page 178835-001