Printronix SL5000e manual Format, Stop RFTAG64

Page 31

 

RFRTAG

 

512 to identify the field

 

number of this particular

 

field.

format

A letter specifying the

 

representation format of

 

the field data.

 

B – binary, D – decimal,

 

H – hexadecimal

NOTE: 1. Multiple RFRTAG commands are allowed in the same form but the same DFn field cannot be defined multiple times.

2.The DF field length is restricted to 64 bits and must be a multiple of 8 bits. The sum of all field lengths must be equal to the tag size.

3.The first field always start at the MSB bit. The bit length of a field dictates the start bit of the next field, etc. As a result, DF fields will not overlap each other.

4.RFRTAG does not allow incremental fields (with the “I” prefix).

5.432 in the ~CREATE line specifies a 6 inch label.

Use 144 for 2 inch labels and 288 for 4 inch labels.

Example

Same as Example 4 on page 29, except the increment is dynamic and the result is merged into Alpha to print on the smart label.

~CREATE;SGTIN–64;432

 

RFWTAG;64

 

2;B;*10*

/Header

3;D;*5*

/Filter Value

14;D;*15383*

/EPC Manager Index

20;D;*123456*

/Object Class

25;IDF1;H

/Serial Number

STOP

 

RFTAG;64

 

64;DF2;H;

 

STOP

 

ALPHA

 

IAF1;16;3;12;0;0

 

STOP

 

31

Image 31
Contents Rfid Labeling Reference Manual Printronix Customer Support Center contact information Rfid Labeling Reference Manual Trademark Acknowledgements Table of Contents Table of Contents Overview Rfid Smart Label Application Reference NotesOverview Factors Affecting Smart Label Performance What To Expect When Running Your Rfid ApplicationFactors Affecting Smart Label Performance Overstruck Smart LabelsWhat To Expect When Running Your Rfid Application Smart Label CharacteristicsHow It Works How Printronix Makes It EasyHow Printronix Makes It Easy Contact Information How To Order More Smart LabelsPrintronix Professional Services What We Can DoContact Information Hardware/Infrastructure ConsiderationsReference Material Useful Industry Web LinksUseful Industry Web Links Smart Label Development Rfid Control Menu Rfid Control MenuCont. from previous Rfid Control Menu Items Error HandlingRfid Control Menu Items Tag Write CntPage Admin User Menu Items Admin User Menu ItemsRfid Test This Test Reads a Tag Custom Tag Len Rfid PGL Commands Rfid PGL CommandsIDFn LengthIDFnformatLength DFnRSTn IdirStep RPTn~CREATESGTIN-64432 RFWTAG64 ExampleStop END ~EXECUTESGTIN-641 ~NORMAL Stop END ~EXECUTESGTIN-64 Rfid PGL Commands ExampleSGTIN-64 ~CREATESGTIN-64432 RFWTAG64 Stop AlphaStop END ~EXECUTESGTIN-64ICNT1500 ~NORMAL ~NORMAL ~EXECUTESGTIN-64Length DFn format Format RFRTAGsizeDF n Stop RFTAG64 FormatStop Format VERIFYfieldformatDASCIIheaderD END ~EXECUTESGTIN-64ICNT1500 ~IDF1STEP+1*0* ~IAF1DF2 ~NORMALASCIIheader Verify~CREATEREADONLY432 RFRTAG64 ~CREATEVERIFY432NOMOTION RFRTAG64Stop RFRTAG64 64DF2H END ~EXECUTEVERIFY1 ~NORMALEND ~EXECUTESIMPLEICNT2000 ~NORMAL ~EXECUTEREADONLY1500 ~NORMAL~CREATESIMPLE432NOMOTION RFWTAG64 Stop Rfrtag 64 64DF1HHEX Write TagFormat RfwriteLock Write TagPosition Read TagFormat RDIposition,length,format RDIGet Tag Unique ID Rfid PPI1 CommandsSet Tag Type Format RT x, start, length, hex, retries, motion, reserved Rfid PPI1 CommandsLCD StartMotion Format HVx,yASCII Host VerificationPPI1 EPC Programming Examples PPI1 EPC Programming ExamplesTools List Software Migration Tools SMTSoftware Migration Tools SMT Tools List Selecting The Tools Rfid MAX Retry Error MessagesControl Panel Error Messages Explanation Solution Selecting The ToolsSetup Guide TroubleshootingTroubleshooting Troubleshooting the Rfid Encoder Symptom SolutionTroubleshooting Troubleshooting Page 178835-001