PPI1 EPC Programming Examples
PPI1 EPC Programming Examples
IMPORTANT For all examples make sure Label Length in the QUICK SETUP menu matches the physical length of the installed media.
Example 1
This programming example programs data into an
RFID tag and prints the encodation onto a smart label.
^XA
//Begin ZPL form.
^WT0^FH^FD_87_D0_03_45_67_AB_CD_EF^FS //Write Tag with data = “87D0034567ABCDEF” //(hex format).
^RT1,0,1,1^FS
//Read Tag into data element 1,
^FO100,100^A0N,60^FN1^FS //Print data in element 1.
^XZ
//End and print label.
Example 2
Same as Example 1, except an alternative PPI1 syntax that does not require underscores between the hex characters is used.
^XA
//Begin ZPL form.
^WT0,,,,1FDN^FD87D0034567ABCDEF^FS
//Write Tag with data = “87D0034567ABCDEF” //(hex format).
^RT1,0,1,1^FS
//Read Tag into data element 1,
^FO100,100^A0N,60^FN1^FS //Print data in element 1.
^XZ
//End and print label.
43