Printronix SL5000r MP manual Trademark Acknowledgements

Page 4

Printronix makes no representations or warranties of any kind regarding this material, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. Printronix shall not be held responsible for errors contained herein or any omissions from this material or for any damages, whether direct, indirect, incidental or consequential, in connection with the furnishing, distribution, performance or use of this material. The information in this manual is subject to change without notice.

This document contains proprietary information protected by copyright. No part of this document may be reproduced, copied, translated or incorporated in any other material in any form or by any means, whether manual, graphic, electronic, mechanical or otherwise, without the prior written consent of Printronix.

COPYRIGHT © 2005, 2006 PRINTRONIX, INC. All rights reserved.

Trademark Acknowledgements

Alien and Alien Technology are registered trademarks of Alien Technology Corporation.

Avery is a trademark of Avery Dennison Corporation.

Impinj is a registered trademark of Impinj, Inc.

Manhattan Associates is a registered trademark of Manhattan Associates, Inc.

Matrics is a registered trademark of Matrics, Inc.

Omron is a trademark of OMRON Corporation.

Printronix, PGL, and PrintNet are registered trademarks of Printronix, Inc.

Rafsec is a registered trademark of Rafsec.

SATO is a registered trademark of SATO America, Inc.

SL5000r is a trademark of Printronix, Inc.

Symbol is a registered trademark of Symbol.

TI is a trademark of Texas Instruments Incorporated.

Uniform Code Council, Inc. is a registered trademark of Uniform Code Council, Inc.

Zebra and ZPL are trademarks of Zebra Technologies Corporation.

Zuma is a trademark of Impinj, Inc.

Image 4
Contents Rfid Labeling Reference Manual Page Rfid Labeling Reference Manual Trademark Acknowledgements Table of Contents MP2 Rfid Table of Contents Table of Contents Rfid Smart Label Application Reference Notes OverviewOverview What To Expect When Running Your Rfid Application Factors Affecting Smart Label PerformanceOverstruck Smart Labels Factors Affecting Smart Label PerformanceSmart Label Characteristics What To Expect When Running Your Rfid ApplicationSupported Tag Types General Tag TypeTechnology Tag Class Smart Label CharacteristicsLabel Size How It Works How Printronix Makes It EasyTransitioning From UCC/GTIN Applications Hardware/Infrastructure Considerations How It WorksPrintronix Professional Services How To Order More Smart LabelsContact Information Printronix Customer Support CenterCorporate Offices Corporate OfficesUseful Industry Web Links Smart Label Development Rfid Control Menu Rfid Control MenuCont. from previous Cust Early Write Custom Run Cal Rfid Control Menu Items Rfid ReaderTag Type Rfid Control Menu ItemsPage Page Page Error Handling Max Retry ErrorLabel Retry Tag Write CntFailed Tag Cnt Tag Void CntTag Read Cnt Clear Tag StatOverstrike Style Admin User Menu Items Read TagRead Tag&Eject PreErase Class 0+Admin User Menu Items Auto RetryCustom Tag Custom Write PwrCustom Read Pwr Custom Tag LenCustom Tag Class Custom Rd TriesCustom Min Power Custom Run CalCustom Tag Pos Custom Start PosCustom Max Power Requesting An Rfid ReportEPC Mgr Report Non-RFID WarningRfid PGL Commands Format RFWTAGLOCKnformatsizemem bank Bit Field+Stop LOCKnformatRfid PGL Commands DF command in the Execute IDF command in the ExecuteStep and startdata parameters using IDF command in the Execute modeRepeated before it is incremented. The default repeat Optional incremental reset count parameter toPrinted before it is reset to the starting value. By Default, there is no reset count. The reset countRfwtag ~CREATESGTIN-64432 RFWTAG64 ExampleStop END ~EXECUTESGTIN-641 ~NORMAL SGTIN-64 ~CREATESGTIN-64432 RFWTAG64 Stop AlphaStop END ~EXECUTESGTIN-64 ~DF4*ABCDEStop END ~EXECUTESGTIN-64ICNT1500 ~NORMAL ~CREATESGTIN-96432 RFWTAG96Stop END ~EXECUTESGTIN-961 ~NORMAL ~CREATESGTIN216RFWTAG96EPC Stop Barcode~CREATESGTIN432 RFWTAGLOCKDF6D96EPCEND ~EXECUTESGTINFCNT3 Format RFRTAGUNLOCKnformatsizemem bank Bit Field+Stop Rfrtag UNLOCKnformatIndicate dynamic data Field to store the readResult. Replace n with a Number ranging from 1 toFormat Stop RFRTAG64Verify Format VERIFYfieldformatDASCIIheaderD DASCIITrailerDASCIIheader ASCIITrailerExample ~CREATEVERIFY432NOMOTION RFRTAG64 Stop RFRTAG64 64DF2HEND ~EXECUTEVERIFY1 ~NORMAL ~CREATEREADONLY432 RFRTAG64Write Tag Rfid PGL Commands ExampleFormat Write Tag RfwriteHEX LockRead Tag Format RDIposition,length,formatRDI PositionRead Tag Rfid PPI/ZGL CommandsFormat RT x, start, length, hex, retries, motion, reserved Rfid PPI/ZGL Commands CommentsStart RetriesWrite or Read Rfid Format Write or Read Rfid FormatFormat RFa,b,c,d Define EPC Data Structure Calibrate Rfid Transponder PositionFormat HRa,b Rfid Setup Enable Rfid MotionSpecify Rfid Retries for a Block Set Rfid Tag Password Format RZaHost Verification PPI/ZGL EPC Programming ExamplesHost Verification Format HVx,y,ASCIIFO100,100A0N,60,60FN1FS //Print tag data in FN1 Escrk 1,a,b,D16,c.c Escrk 1,a,b,D24,c.c Rfid Write Rfid PPI/STGL CommandsPPI/ZGL EPC Programming Examples Return Status Port Return Status PortTools List Software Migration Tools SMTTools List Page Selecting The Tools Selecting The ToolsError Messages Error MessagesControl Panel Error Messages Explanation Solution Rfid MAX Retry Rfid TAG ERRRfid TAG Failed Rfid Unlock CMDTroubleshooting TroubleshootingTroubleshooting the Rfid Encoder Symptom Solution Setup GuideMP2 Rfid New Coupler SystemAdjusting The Coupler Position New Coupler SystemBit And 96 Bit EPC Data Formats Class 1 GenGen Class 0+, Class Zuma, and ClassRequest from Result Comment PGL EPC Format Handling Selected Size of Data Based onLength Program 64 bit Pad 0s on right for 64 bit = 64 bit When 64 Bit Data Is Sent To a 96 Bit Tag PGL Moving From 64 Bit Tags To 96 Bit TagsExample Moving From 64 Bit Tags To 96 Bit TagsWhen 64 Bit Data Is Sent To a 96 Bit Tag ZGL When 64 Bit Data Is Sent To a 96 Bit Tag ZGL~NORMAL ~CREATETEST1216 RFWTAG64 Multiple Read/Write Commands On One Label ~NORMAL ~CREATETEST1NOMOTION RFRTAG64END ~EXECUTETEST1 ~NORMAL ~CREATETEST1 RFWTAG64 END ~EXECUTETEST1 ~NORMALVerify Command is not Rfid Specific Verify Command is not Rfid SpecificSplitting the EPC Customer ScenarioSimplest Solution Splitting the EPCTag Profiler Using The Advanced Rfid CalibrationTag Profiler Using The Advanced Rfid Calibration Custom Tag ConfiguratorAuto Inlay Locater Page 178424-001