Printronix SL5000r MP manual ASCIIheader, ASCIITrailer

Page 49

VERIFY

always S type. The DFn format could be either B, D, or H. Due to the possible conversion the outgoing datastream could be longer than the incoming one. The maximum length for the outgoing data is 512 bytes. If the format request will result in a datastream exceeding the maximum length, an error would be reported.

ASCIIheader

A mandatory parameter to specify an ASCII string of characters, which is followed by the RFID data, to be sent by the printer to the host.

(D)Delimiter designating the start and end of a character string. Replace (D) with any printable character, except the SFCC and the slash character (/). The string could be empty, i.e. there are not headers preceeding the field data.

ASCIITrailer

Optional parameter to append an ASCII string of characters to the RFID data. You can insert the LF/CR characters \r\n into the string.

NOTE: 1. The DFn field must be defined previously in the CREATE mode before it can be specified in the VERIFY command otherwise it will be considered as a syntax error and the VERIFY command will abort.

2.All RFID Read/Write commands are executed first in the order they appear in CREATE mode, followed by Alpha and Barcode commands, and finally VERIFY commands. The VERIFY commands are always executed last although they may appear before other commands in the CREATE mode. The reason for this is to make sure the data are sent back to the host only if other commands are completed and the form is not aborted.

3.If the data comes from a DFn field, the DFn format is the original format before any conversion. If the VERIFY

49

Image 49
Contents Rfid Labeling Reference Manual Page Rfid Labeling Reference Manual Trademark Acknowledgements Table of Contents MP2 Rfid Table of Contents Table of Contents Overview Rfid Smart Label Application Reference NotesOverview Factors Affecting Smart Label Performance What To Expect When Running Your Rfid ApplicationOverstruck Smart Labels Factors Affecting Smart Label PerformanceWhat To Expect When Running Your Rfid Application Smart Label CharacteristicsSupported Tag Types General Tag TypeTechnology Tag Class Smart Label CharacteristicsLabel Size How It Works How Printronix Makes It EasyTransitioning From UCC/GTIN Applications How It Works Hardware/Infrastructure ConsiderationsHow To Order More Smart Labels Printronix Professional ServicesContact Information Printronix Customer Support CenterCorporate Offices Corporate OfficesUseful Industry Web Links Smart Label Development Rfid Control Menu Rfid Control MenuCont. from previous Cust Early Write Custom Run Cal Rfid Reader Rfid Control Menu ItemsTag Type Rfid Control Menu ItemsPage Page Page Max Retry Error Error HandlingLabel Retry Tag Write CntTag Void Cnt Failed Tag CntTag Read Cnt Clear Tag StatOverstrike Style Read Tag Admin User Menu ItemsRead Tag&Eject PreErase Class 0+Auto Retry Admin User Menu ItemsCustom Tag Custom Write PwrCustom Tag Len Custom Read PwrCustom Tag Class Custom Rd TriesCustom Run Cal Custom Min PowerCustom Tag Pos Custom Start PosRequesting An Rfid Report Custom Max PowerEPC Mgr Report Non-RFID WarningFormat RFWTAGLOCKnformatsizemem bank Bit Field+ Rfid PGL CommandsStop LOCKnformatRfid PGL Commands IDF command in the Execute DF command in the ExecuteStep and startdata parameters using IDF command in the Execute modeOptional incremental reset count parameter to Repeated before it is incremented. The default repeatPrinted before it is reset to the starting value. By Default, there is no reset count. The reset countRfwtag ~CREATESGTIN-64432 RFWTAG64 ExampleStop END ~EXECUTESGTIN-641 ~NORMAL Stop Alpha SGTIN-64 ~CREATESGTIN-64432 RFWTAG64Stop END ~EXECUTESGTIN-64 ~DF4*ABCDE~CREATESGTIN-96432 RFWTAG96 Stop END ~EXECUTESGTIN-64ICNT1500 ~NORMAL~CREATESGTIN216 Stop END ~EXECUTESGTIN-961 ~NORMALRFWTAG96EPC Stop BarcodeRFWTAGLOCKDF6D96EPC ~CREATESGTIN432Format RFRTAGUNLOCKnformatsizemem bank Bit Field+ END ~EXECUTESGTINFCNT3Stop Rfrtag UNLOCKnformatField to store the read Indicate dynamic dataResult. Replace n with a Number ranging from 1 toStop RFRTAG64 FormatFormat VERIFYfieldformatDASCIIheaderD DASCIITrailerD VerifyASCIITrailer ASCIIheaderExample Stop RFRTAG64 64DF2H ~CREATEVERIFY432NOMOTION RFRTAG64END ~EXECUTEVERIFY1 ~NORMAL ~CREATEREADONLY432 RFRTAG64Write Tag Rfid PGL Commands ExampleFormat Rfwrite Write TagHEX LockFormat RDIposition,length,format Read TagRDI PositionRead Tag Rfid PPI/ZGL CommandsFormat RT x, start, length, hex, retries, motion, reserved Comments Rfid PPI/ZGL CommandsStart RetriesWrite or Read Rfid Format Write or Read Rfid FormatFormat RFa,b,c,d Define EPC Data Structure Calibrate Rfid Transponder PositionFormat HRa,b Rfid Setup Enable Rfid MotionSpecify Rfid Retries for a Block Format RZa Set Rfid Tag PasswordPPI/ZGL EPC Programming Examples Host VerificationHost Verification Format HVx,y,ASCIIFO100,100A0N,60,60FN1FS //Print tag data in FN1 Escrk 1,a,b,D16,c.c Escrk 1,a,b,D24,c.c Rfid Write Rfid PPI/STGL CommandsPPI/ZGL EPC Programming Examples Return Status Port Return Status PortTools List Software Migration Tools SMTTools List Page Selecting The Tools Selecting The ToolsError Messages Error MessagesControl Panel Error Messages Explanation Solution Rfid TAG ERR Rfid MAX RetryRfid TAG Failed Rfid Unlock CMDTroubleshooting TroubleshootingTroubleshooting the Rfid Encoder Symptom Solution Setup GuideNew Coupler System MP2 RfidNew Coupler System Adjusting The Coupler PositionClass 1 Gen Bit And 96 Bit EPC Data FormatsGen Class 0+, Class Zuma, and ClassRequest from Result Comment PGL EPC Format Handling Selected Size of Data Based onLength Program 64 bit Pad 0s on right for 64 bit = 64 bit Moving From 64 Bit Tags To 96 Bit Tags When 64 Bit Data Is Sent To a 96 Bit Tag PGLExample Moving From 64 Bit Tags To 96 Bit TagsWhen 64 Bit Data Is Sent To a 96 Bit Tag ZGL When 64 Bit Data Is Sent To a 96 Bit Tag ZGL~NORMAL ~CREATETEST1216 RFWTAG64 ~NORMAL ~CREATETEST1NOMOTION RFRTAG64 Multiple Read/Write Commands On One LabelEND ~EXECUTETEST1 ~NORMAL ~CREATETEST1 RFWTAG64 END ~EXECUTETEST1 ~NORMALVerify Command is not Rfid Specific Verify Command is not Rfid SpecificSplitting the EPC Customer ScenarioSplitting the EPC Simplest SolutionTag Profiler Using The Advanced Rfid CalibrationTag Profiler Using The Advanced Rfid Calibration Custom Tag ConfiguratorAuto Inlay Locater Page 178424-001