Printronix SL5000r MP Optional incremental repeat count parameters to, From 1 to, Mentioned above

Page 38

Chapter 2 RFID PGL Commands

idir

Enter a plus sign (+) or leave the field blank to

 

increment (default). Enter a minus sign (–) to

 

decrement.

step

A decimal number specifies the amount to increment/

 

decrement each time the form is executed. The

 

increment is at bit level and will automatically wrap

 

based on the field size.

RPTn

The optional incremental repeat count parameters to

 

specify the number of times a particular field value is

 

repeated before it is incremented. The default repeat

 

count parameter n is 1, which will increment the field

 

value each time it prints. The repeat count can range

 

from 1 to 65535.

RSTn

The optional incremental reset count parameter to

 

specify the number of times an incremented field is

 

printed before it is reset to the starting value. By

 

default, there is no reset count. The reset count

 

parameter n can range from 1 to 65535.

startdata

Defines the value of the field or the starting value of the

 

incremented field. If the field is dynamic, the value will

 

be specified later in the EXECUTE mode. The data

 

must be specified within a pair of delimiters (D). The

 

delimiter (D) cannot be a “/” or SFCC character since

 

the “/” will comment out the rest of the line and SFCC is

 

reserved for PGL commands. If “R” or “S” is used as

 

delimiters, the data pattern must not comprise of the

 

keywords in the incrementing options. Since the

 

delimiters could be different from one value to another,

 

proper care must be taken to avoid one of the letters

 

mentioned above.

NOTE: 1. The RFWTAG command cannot be mixed with RFWRITE in the same form.

2.Each field structure must be specified in a single line and in the order it appears in the RFID tag from MSB bits to LSB bits (left to right). The sum of all the field lengths must match the size of the tag.

3.The host data are read in as ASCII characters. They would be converted to binary representation for the base

38

Image 38
Contents Rfid Labeling Reference Manual Page Rfid Labeling Reference Manual Trademark Acknowledgements Table of Contents MP2 Rfid Table of Contents Table of Contents Rfid Smart Label Application Reference Notes OverviewOverview Overstruck Smart Labels What To Expect When Running Your Rfid ApplicationFactors Affecting Smart Label Performance Factors Affecting Smart Label PerformanceSupported Tag Types Smart Label CharacteristicsWhat To Expect When Running Your Rfid Application General Tag TypeLabel Size Smart Label CharacteristicsTechnology Tag Class Transitioning From UCC/GTIN Applications How Printronix Makes It EasyHow It Works Hardware/Infrastructure Considerations How It WorksContact Information Printronix Professional ServicesHow To Order More Smart Labels Printronix Customer Support CenterCorporate Offices Corporate OfficesUseful Industry Web Links Smart Label Development Rfid Control Menu Rfid Control MenuCont. from previous Cust Early Write Custom Run Cal Tag Type Rfid Control Menu ItemsRfid Reader Rfid Control Menu ItemsPage Page Page Label Retry Error HandlingMax Retry Error Tag Write CntTag Read Cnt Failed Tag CntTag Void Cnt Clear Tag StatOverstrike Style Read Tag&Eject Admin User Menu ItemsRead Tag PreErase Class 0+Custom Tag Admin User Menu ItemsAuto Retry Custom Write PwrCustom Tag Class Custom Read PwrCustom Tag Len Custom Rd TriesCustom Tag Pos Custom Min PowerCustom Run Cal Custom Start PosEPC Mgr Report Custom Max PowerRequesting An Rfid Report Non-RFID WarningStop Rfid PGL CommandsFormat RFWTAGLOCKnformatsizemem bank Bit Field+ LOCKnformatRfid PGL Commands Step and startdata parameters using DF command in the ExecuteIDF command in the Execute IDF command in the Execute modePrinted before it is reset to the starting value. By Repeated before it is incremented. The default repeatOptional incremental reset count parameter to Default, there is no reset count. The reset countRfwtag Stop END ~EXECUTESGTIN-641 ~NORMAL Example~CREATESGTIN-64432 RFWTAG64 Stop END ~EXECUTESGTIN-64 SGTIN-64 ~CREATESGTIN-64432 RFWTAG64Stop Alpha ~DF4*ABCDEStop END ~EXECUTESGTIN-64ICNT1500 ~NORMAL ~CREATESGTIN-96432 RFWTAG96RFWTAG96EPC Stop END ~EXECUTESGTIN-961 ~NORMAL~CREATESGTIN216 Stop Barcode~CREATESGTIN432 RFWTAGLOCKDF6D96EPCStop Rfrtag END ~EXECUTESGTINFCNT3Format RFRTAGUNLOCKnformatsizemem bank Bit Field+ UNLOCKnformatResult. Replace n with a Indicate dynamic dataField to store the read Number ranging from 1 toFormat Stop RFRTAG64Verify Format VERIFYfieldformatDASCIIheaderD DASCIITrailerDASCIIheader ASCIITrailerExample END ~EXECUTEVERIFY1 ~NORMAL ~CREATEVERIFY432NOMOTION RFRTAG64Stop RFRTAG64 64DF2H ~CREATEREADONLY432 RFRTAG64Format Rfid PGL Commands ExampleWrite Tag HEX Write TagRfwrite LockRDI Read TagFormat RDIposition,length,format PositionFormat RT x, start, length, hex, retries, motion, reserved Rfid PPI/ZGL CommandsRead Tag Start Rfid PPI/ZGL CommandsComments RetriesFormat RFa,b,c,d Write or Read Rfid FormatWrite or Read Rfid Format Format HRa,b Calibrate Rfid Transponder PositionDefine EPC Data Structure Specify Rfid Retries for a Block Enable Rfid MotionRfid Setup Set Rfid Tag Password Format RZaHost Verification Host VerificationPPI/ZGL EPC Programming Examples Format HVx,y,ASCIIFO100,100A0N,60,60FN1FS //Print tag data in FN1 PPI/ZGL EPC Programming Examples Rfid PPI/STGL CommandsEscrk 1,a,b,D16,c.c Escrk 1,a,b,D24,c.c Rfid Write Return Status Port Return Status PortTools List Software Migration Tools SMTTools List Page Selecting The Tools Selecting The ToolsControl Panel Error Messages Explanation Solution Error MessagesError Messages Rfid TAG Failed Rfid MAX RetryRfid TAG ERR Rfid Unlock CMDTroubleshooting the Rfid Encoder Symptom Solution TroubleshootingTroubleshooting Setup GuideMP2 Rfid New Coupler SystemAdjusting The Coupler Position New Coupler SystemGen Bit And 96 Bit EPC Data FormatsClass 1 Gen Class 0+, Class Zuma, and ClassLength Program PGL EPC Format Handling Selected Size of Data Based onRequest from Result Comment 64 bit Pad 0s on right for 64 bit = 64 bit Example When 64 Bit Data Is Sent To a 96 Bit Tag PGLMoving From 64 Bit Tags To 96 Bit Tags Moving From 64 Bit Tags To 96 Bit Tags~NORMAL ~CREATETEST1216 RFWTAG64 When 64 Bit Data Is Sent To a 96 Bit Tag ZGLWhen 64 Bit Data Is Sent To a 96 Bit Tag ZGL END ~EXECUTETEST1 ~NORMAL ~CREATETEST1 RFWTAG64 Multiple Read/Write Commands On One Label~NORMAL ~CREATETEST1NOMOTION RFRTAG64 END ~EXECUTETEST1 ~NORMALSplitting the EPC Verify Command is not Rfid SpecificVerify Command is not Rfid Specific Customer ScenarioSimplest Solution Splitting the EPCTag Profiler Using The Advanced Rfid CalibrationTag Profiler Auto Inlay Locater Custom Tag ConfiguratorUsing The Advanced Rfid Calibration Page 178424-001