//this will display “Head=<tag data>Tail<CR><LF>”

Chapter 2 RFID PGL Commands

command specifies a different format, the data would then be converted to the new format. If the data comes from an AFn or BFn, the original format is S format.

4.432 in the ~CREATE line specifies a 6 inch label. Use 144 for 2 inch labels and 288 for 4 inch labels.

5.Below is the possible syntax for header and trailer string:

1.

VERIFY;DF2;H;*Head = *

//Header only

2.

VERIFY;DF2;H;*Head = *; *Tail*

//Header & trailer

3.

VERIFY;DF2;H;**;*Tail*

//Trailer only

4.

VERIFY;DF2;H;*Head = *;**

//Header only

To insert the CR/LF character, add “\r” and “\n” as CR/LF characters, such as

VERIFY;DF2;H;*Head=*; *Tail\r\n*

If the user wants to display “\r” or “\n” as normal text character, do the following:

VERIFY;DF2;H;*Header\\r\\n*

//this will display

 

“Header\r\n” on the

 

screen, where double

 

back slash “\\”

 

(0x5C0x5C) will be

 

replaced with one

 

back slash “\” (0x5C).

The characters \r and \n can be inserted anywhere in the header string and trailer string.

To summarize,

 

\r –> 0x0D

//CR

\n –> 0x0A

//LF

\\ –> \

//one back slash

Example 1

This example requests the printer to send to the host the content of the RFID tag, in hexadecimal format, both before and after the RFWTAG command writes data to the tag. Also, the label is not moved.

50

Image 50
Contents Rfid Labeling Reference Manual Page Rfid Labeling Reference Manual Trademark Acknowledgements Table of Contents MP2 Rfid Table of Contents Table of Contents Rfid Smart Label Application Reference Notes OverviewOverview Overstruck Smart Labels What To Expect When Running Your Rfid ApplicationFactors Affecting Smart Label Performance Factors Affecting Smart Label PerformanceSupported Tag Types Smart Label CharacteristicsWhat To Expect When Running Your Rfid Application General Tag TypeLabel Size Smart Label CharacteristicsTechnology Tag Class Transitioning From UCC/GTIN Applications How Printronix Makes It EasyHow It Works Hardware/Infrastructure Considerations How It WorksContact Information Printronix Professional ServicesHow To Order More Smart Labels Printronix Customer Support CenterCorporate Offices Corporate OfficesUseful Industry Web Links Smart Label Development Rfid Control Menu Rfid Control MenuCont. from previous Cust Early Write Custom Run Cal Tag Type Rfid Control Menu ItemsRfid Reader Rfid Control Menu ItemsPage Page Page Label Retry Error HandlingMax Retry Error Tag Write CntTag Read Cnt Failed Tag CntTag Void Cnt Clear Tag StatOverstrike Style Read Tag&Eject Admin User Menu ItemsRead Tag PreErase Class 0+Custom Tag Admin User Menu ItemsAuto Retry Custom Write PwrCustom Tag Class Custom Read PwrCustom Tag Len Custom Rd TriesCustom Tag Pos Custom Min PowerCustom Run Cal Custom Start PosEPC Mgr Report Custom Max PowerRequesting An Rfid Report Non-RFID WarningStop Rfid PGL CommandsFormat RFWTAGLOCKnformatsizemem bank Bit Field+ LOCKnformatRfid PGL Commands Step and startdata parameters using DF command in the ExecuteIDF command in the Execute IDF command in the Execute modePrinted before it is reset to the starting value. By Repeated before it is incremented. The default repeatOptional incremental reset count parameter to Default, there is no reset count. The reset countRfwtag Stop END ~EXECUTESGTIN-641 ~NORMAL Example~CREATESGTIN-64432 RFWTAG64 Stop END ~EXECUTESGTIN-64 SGTIN-64 ~CREATESGTIN-64432 RFWTAG64Stop Alpha ~DF4*ABCDEStop END ~EXECUTESGTIN-64ICNT1500 ~NORMAL ~CREATESGTIN-96432 RFWTAG96RFWTAG96EPC Stop END ~EXECUTESGTIN-961 ~NORMAL~CREATESGTIN216 Stop Barcode~CREATESGTIN432 RFWTAGLOCKDF6D96EPCStop Rfrtag END ~EXECUTESGTINFCNT3Format RFRTAGUNLOCKnformatsizemem bank Bit Field+ UNLOCKnformatResult. Replace n with a Indicate dynamic dataField to store the read Number ranging from 1 toFormat Stop RFRTAG64Verify Format VERIFYfieldformatDASCIIheaderD DASCIITrailerDASCIIheader ASCIITrailerExample END ~EXECUTEVERIFY1 ~NORMAL ~CREATEVERIFY432NOMOTION RFRTAG64Stop RFRTAG64 64DF2H ~CREATEREADONLY432 RFRTAG64Format Rfid PGL Commands ExampleWrite Tag HEX Write TagRfwrite LockRDI Read TagFormat RDIposition,length,format PositionFormat RT x, start, length, hex, retries, motion, reserved Rfid PPI/ZGL CommandsRead Tag Start Rfid PPI/ZGL CommandsComments RetriesFormat RFa,b,c,d Write or Read Rfid FormatWrite or Read Rfid Format Format HRa,b Calibrate Rfid Transponder PositionDefine EPC Data Structure Specify Rfid Retries for a Block Enable Rfid MotionRfid Setup Set Rfid Tag Password Format RZaHost Verification Host VerificationPPI/ZGL EPC Programming Examples Format HVx,y,ASCIIFO100,100A0N,60,60FN1FS //Print tag data in FN1 PPI/ZGL EPC Programming Examples Rfid PPI/STGL CommandsEscrk 1,a,b,D16,c.c Escrk 1,a,b,D24,c.c Rfid Write Return Status Port Return Status PortTools List Software Migration Tools SMTTools List Page Selecting The Tools Selecting The ToolsControl Panel Error Messages Explanation Solution Error MessagesError Messages Rfid TAG Failed Rfid MAX RetryRfid TAG ERR Rfid Unlock CMDTroubleshooting the Rfid Encoder Symptom Solution TroubleshootingTroubleshooting Setup GuideMP2 Rfid New Coupler SystemAdjusting The Coupler Position New Coupler SystemGen Bit And 96 Bit EPC Data FormatsClass 1 Gen Class 0+, Class Zuma, and ClassLength Program PGL EPC Format Handling Selected Size of Data Based onRequest from Result Comment 64 bit Pad 0s on right for 64 bit = 64 bit Example When 64 Bit Data Is Sent To a 96 Bit Tag PGLMoving From 64 Bit Tags To 96 Bit Tags Moving From 64 Bit Tags To 96 Bit Tags~NORMAL ~CREATETEST1216 RFWTAG64 When 64 Bit Data Is Sent To a 96 Bit Tag ZGLWhen 64 Bit Data Is Sent To a 96 Bit Tag ZGL END ~EXECUTETEST1 ~NORMAL ~CREATETEST1 RFWTAG64 Multiple Read/Write Commands On One Label~NORMAL ~CREATETEST1NOMOTION RFRTAG64 END ~EXECUTETEST1 ~NORMALSplitting the EPC Verify Command is not Rfid SpecificVerify Command is not Rfid Specific Customer ScenarioSimplest Solution Splitting the EPCTag Profiler Using The Advanced Rfid CalibrationTag Profiler Auto Inlay Locater Custom Tag ConfiguratorUsing The Advanced Rfid Calibration Page 178424-001