Telenetics 14.4, 2.4, 28.8, 9.6 manual General Product Specifications, Vdc

Page 7

3.GENERAL PRODUCT SPECIFICATIONS

Dimensions:

 

5.3 x 4.0 x 1.375 inches

Weight:

 

1 lb

 

Voltage Supply:

:

8 to 24

VDC

 

 

7 to 16

VAC, 50/60 Hz

 

Optional Wall Transformer

115 VAC, 50/60 Hz

Current Requirements: (See Section 4 for Power Down Modes)

MIU PowerPort 2.4:

 

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

65mA

27mA

7.5mA

6.5mA

5.5mA

MIU PowerPort 9.6:

 

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

115mA

57mA

11mA

10mA

9mA

MIU1 PowerPort 4.4:

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

160mA

69mA

14mA

12mA

9mA

MIU PowerPort 28.8:

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

205mA

125mA

16mA

15mA

11mA

Surge Protection:

Power Supply:

8kVrms

 

 

 

Analog Line:

5kVac (MIU2.4 & 9.6)

 

 

 

3.75kVac (MIU14.4 & 28.8)

 

 

Digital Line:

ESD ± 10kV

 

Operating Temperature:

-40 to +85 deg C

Operating Humidity:

 

0 to 90% (non-condensing.)

Storage Temperature:

 

-55 to 100 deg C

*Note: At temperatures below 0° F, an additional current drain of up to 350 ma occurs as the internal proportional heater operates.

MIU Installation, Operation & Diagnostics Edition: January 25, 1999

Page 5

Image 7
Contents Installation, Operation & Diagnostics Telenetics Corporation Table of Contents USA StandardsProduct Overview MIU Installation, Operation & Diagnostics Edition January 25 VDC General Product SpecificationsSleep Power ModesMode Description Power Consumption Power On Power DownMIU2.4 MIU9.6 MIU14.4 MIU28.8 Modem SpecificationsPower Connections Serial Data Port PIN-OUTS DIP Switch Settings Auto Reset Feature LED IndicatorAuto Dial Feature Outline Drawing & Mounting Modem Configuration Stored Profile Factory Configuration ~ MIU2.4 Active ProfileTelephone Numbers &Z0= Telephone Numbers Factory Configuration ~ MIU9.6 Active ProfileFactory Configuration ~ MIU14.4 Active Profile Factory Configuration ~ MIU28.8 Active Profile Diagnostics T1 Initiate Local Analog Loopback See Figure T0 Terminate Test in ProgressResult Code Description Perform Local Digital Loopback See Figure No FunctionGrant Remote Digital Loopback RDL Requests T6 Initiate Remote Digital Loopback See Figure T5 Deny RDL RequestsT7 Initiate RDL with Local Self Test See Figure Result Codes Description T6, &T7, or if on-line T8 Local Loopback with Self Test See FigureMIU Installation, Operation & Diagnostics Edition January 25 MIU Installation, Operation & Diagnostics Edition January 25 MIU Installation, Operation & Diagnostics Edition January 25 S86 Connection Failure Cause Received Line Signal QualityMIU Installation, Operation & Diagnostics Edition January 25 MIU Installation, Operation & Diagnostics Edition January 25