4.POWER MODES

Mode

Description

Power

 

 

Consumption

Power On

Factory Setting: Full power is always

See Section 3

 

available to the modem.

 

Sleep

If the modem is on hook for a

Approx. 6mA

 

predetermined period (PE2400 = 5

 

 

seconds; PE2496, PE14.4 & PE28.8 =

 

 

software configured: Set S24 to desired

 

 

delay in seconds), it will drop to a low

 

 

current mode).

 

 

The modem will instantly “wake up” to

 

 

full power by either an incoming ring

 

 

signal or any transmit data (TxD) signal.

 

 

 

 

Power Down

If the modem is on hook for 30 seconds,

Approx. 20µA

 

it will automatically turn “off”.

 

 

The modem will automatically turn “on”

 

 

to full power within 400ms of receiving a

 

 

DTR signal or an incoming call.

 

 

 

 

 

 

 

The power mode is set by a dip switch on the Pony Express Modem Module inside the MIU case. Factory default is Power On mode. Other modes are set at the factory before shipment if requested. Other modes can be set in the field ~ call Telenetics for an instruction sheet.

MIU Installation, Operation & Diagnostics Edition: January 25, 1999

Page 6

Image 8
Contents Installation, Operation & Diagnostics Telenetics Corporation Table of Contents Standards USAProduct Overview MIU Installation, Operation & Diagnostics Edition January 25 General Product Specifications VDCPower Modes Mode Description Power Consumption Power OnPower Down SleepModem Specifications MIU2.4 MIU9.6 MIU14.4 MIU28.8Power Connections Serial Data Port PIN-OUTS DIP Switch Settings Auto Dial Feature LED IndicatorAuto Reset Feature Outline Drawing & Mounting Modem Configuration Telephone Numbers &Z0= Factory Configuration ~ MIU2.4 Active ProfileStored Profile Factory Configuration ~ MIU9.6 Active Profile Telephone NumbersFactory Configuration ~ MIU14.4 Active Profile Factory Configuration ~ MIU28.8 Active Profile Diagnostics Result Code Description T0 Terminate Test in ProgressT1 Initiate Local Analog Loopback See Figure Grant Remote Digital Loopback RDL Requests No FunctionPerform Local Digital Loopback See Figure T7 Initiate RDL with Local Self Test See Figure T5 Deny RDL RequestsT6 Initiate Remote Digital Loopback See Figure Result Codes Description T8 Local Loopback with Self Test See Figure T6, &T7, or if on-lineMIU Installation, Operation & Diagnostics Edition January 25 MIU Installation, Operation & Diagnostics Edition January 25 MIU Installation, Operation & Diagnostics Edition January 25 Received Line Signal Quality S86 Connection Failure CauseMIU Installation, Operation & Diagnostics Edition January 25 MIU Installation, Operation & Diagnostics Edition January 25