Telenetics MIU202T-S manual Local Analog Loopback Figure, Test 1 RTS/CTS Analog Control

Page 19

13.DIAGNOSTICS

The following pages provide hardware techniques for diagnosing communication problems and thereby isolating the problem at the local modem, the remote modem or the interconnecting line.

(a)LOCAL ANALOG LOOPBACK (Figure 2)

Requires a loop back cable with a built-in circuit for line loss to simulate a typical leased line condition (See Figure 3).

Connect the loop back cable to the RJ11 connector on the modem under test.

Set Dip Switches as follows…

Switch 7 = OFF

4-Wire

Switch 9

= ON

Soft Carrier Turn Off Enabled

Switch 1

= ON

Transmit (TxA) Signal Level = 0dBm

Switch 3

= ON

Receive (RxA) Signal Level = –33dBm

Switch 6

= OFF

Switched Carrier

Switch 4&5 = ON

RTS/CTS Delay = 50ms

Test 1: RTS/CTS Analog Control

Set RTS “ON” and check that CD (Carrier Detect) turns “ON”.

Turn RTS “OFF” and ensure that CD turns “OFF”

With RTS “ON”, run a test message at TxD and verify that the same message is received at RxD with no data errors.

Test 2: Transmit Signal Power & Receive Levels

Set Dip Switch 1 OFF (TxA = -10dBm)

CD will be OFF.

Change Dip Switch 1 to ON (TxA = 0dBm)

CD should now be ON.

Test 3: Received Signal Level

MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 17

Image 19
Contents MIU202T-S Telenetics Corporation Page Page Product Overview Operating Temperature DimensionsWeight Surge Protection Power SupplySynch/Async Error CorrectionModulation Modulation TypeOther Features Dip Switch Selectable ~ See SectionAnalog Line Type Analog Line Specifications3400Hz -3, +0.7 dB Page Power Connections Serial Data Port PIN-OUTS OFF Wire RTS/CTS Delay TimeFor clarity, a blank space = OFF LED Indicator Outline Drawing & Mounting Test 1 RTS/CTS Analog Control Test 2 Transmit Signal Power & Receive LevelsTest 3 Received Signal Level Local Analog Loopback FigurePage Page Adjustments… Line DiagnosticsPage Page