4. MODEM SPECIFICATIONS

 

 

Modulation:

Bell202T

Modulation Type:

FSK

 

Synch/Async:

Synchronous or Asynchronous

Data Rate:

0 – 1200bps

Transmit Frequency:

Mark:

1200Hz

 

Space:

2200Hz

Error Correction:

None

 

Data Compression:

None

 

Data Modulation Connectivity:

Using 16ms Polling Test

99.999% or better at -37dBm

99.5% or better at -40dBm

95% or better at -43dBm

Serial Formats and Flow Control:

Synchronous or Asynchronous and RTS/CTS flow control

Analog Interface

Tx Output Level:

Rx Sensitivity:

Line Termination:

Line Impedance:

2 or 4 Wire Configuration:

-0 dBm or -10 dBm * -43dBm or -33dBm * -43dBm for constant carrier -40dBm for polling carrier Dip Switch Selectable * 600 ohms balanced

Dip Switch Selectable *

MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 5

Image 7
Contents MIU202T-S Telenetics Corporation Page Page Product Overview Operating Temperature DimensionsWeight Surge Protection Power SupplySynch/Async Error CorrectionModulation Modulation TypeOther Features Dip Switch Selectable ~ See SectionAnalog Line Type Analog Line Specifications3400Hz -3, +0.7 dB Page Power Connections Serial Data Port PIN-OUTS OFF Wire RTS/CTS Delay TimeFor clarity, a blank space = OFF LED Indicator Outline Drawing & Mounting Test 1 RTS/CTS Analog Control Test 2 Transmit Signal Power & Receive LevelsTest 3 Received Signal Level Local Analog Loopback FigurePage Page Adjustments… Line DiagnosticsPage Page