Operation2 5
Start-Up Sequence
This stove utilizes a
"MANUAL AUGER" Button
This button turns the auger on. It is used to “prime” the auger after the hopper has run out of pellets.
"AUGER ON" Light
This light comes on when the auger is turning. This allows the operator to determine when the auger is turning.
"FAULT" Light
This light comes on when an error occurs:
•The stove runs out of pellets
•During initial
•A
To reset the fault light, turn the mode switch to off and
DISCONNECT POWER BEFORE SERVICE
H |
|
E | REMOTE |
A | HIGH |
T | AUTO |
| |
| MANUAL |
OMED
U
TAUGER
P LOW
U | FAULT |
T |
|
Fault Codes (for qualified service personnel only)
Fault and #2 (LOW) Light Flash = Flow Switch Fault
Fault and # 4 (MID) Light Flash = System Snap Disk Fault (pellets run out & stove goes cold)
Fault and # 6 (HIGH) Light Flash = Safety Snap Disk Fault
Power Outages
If a sustained power outage occurs while in "Manual", the stove will go to a "cool down" mode to vacate smoke once power returns. If the power outage was short, the heater will go to the
!Because this stove relies upon a blower to evacuate the smoke, some smoke may enter the home during a power outage. To keep to a minimum, leave the door closed.
Travis Industries | 4061016 | 1 0 0 - 0 1 1 8 4 |