3 6Maintenance

Yearly Maintenance (or every two tons) - continued

Clean the Exhaust Blower

The exhaust blower cover is held in place with 4 screws.

Remove the side cover.

Remove the cover plate on the exhaust blower. Clean the area inside the blower, removing all flyash.

Remove these 3 nuts to expose the exhaust blower.

Flow Switch Tube

Use the bottle brush to disoldge any flyash near the exahust blower and in the horizontal exhaust channel. Take care to not damage the impeller on the exhaust blower.

Nipple (attached to exhaust channel)

Check the nipple and flow switch tube. Insert a pipe cleaner through the nipple to dislodge any flyash. NOTE: The flow switch will shut off the auger if the tube becomes clogged or dislodged. Make sure it is cleaned out and correctly attached.

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Page 36
Image 36
Lopi Leyden Pellet Stove manual 6Maintenance, Clean the Exhaust Blower