Maintenance3 1

Bi-Weekly Maintenance (or every 10 bags of pellets) - continued

Clean the Baffles

WARNING: Make sure the heater has fully cooled (approximately 25 minutes) before conducting service.

HINT: The more often you clean out flyash, the more efficient your heater will burn.

The baffles are found along the top of the firebox. The front edge has a slot that slides into a hook on the top of the firebox. The back rests on the back refractory. To remove, slide them inwards, pull them forward, and tilt them back to allow the accumulated flyash fall off into the firebox. Replace after cleaning.

Push up on the front portion of the left baffle and slide it to the right. Note how the rear edge of the baffle rests on the rear refractory.

Move the baffle forward and tilt the back down. This allows any built-up flyash to fall off the top of the baffle.

The right side baffle is removed in the same fashion. Note how the right side baffle is larger than the left side baffle.

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Page 31
Image 31
Lopi Leyden Pellet Stove manual Maintenance3, Bi-Weekly Maintenance or every 10 bags of pellets, Clean the Baffles