1 0 Installation (For Qualified Installers Only)

1 0 Installation (For Qualified Installers Only)

Pellet Vent Type

Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc… ) must be sealed with 500° F. RTV silicone.

Installing the Pellet Vent

.RTV °F 500Silicone

Seal each vent section (including adapters, elbows, etc...) by

injecting a liberal amount of 500° F. RTV silicone into the gap

between sections.

Horizontal sections must have a 1/4" rise every 12" of travel.

Pellet vent connections must be sealed airtight with 500° F. RTV silicone and screwed together with at least three sheet metal screws.

Pellet Vent Termination

Vent must terminate on the exterior of the dwelling. Horizontal terminations must protrude a minimum12" from the wall. Vertical terminations must protrude a minimum 24" from the roof surface. In addition, all clearances listed below must be met.

Must have an approved cap (to prevent water from entering) or a 45° downturn with rodent screen.

If the termination is located on a windy side of the house, an approved house shield is recommended to prevent soot from building up on the side of the house.

Must not be located where it will become plugged by snow or other material.

C

H

X Pellet Vent Type

A

Installing the Pellet Vent B

H Pellet Vent TerminationManual background F Manual backgroundManual background AManual background

E

G

F

D

Manual background NOTE: Measure clearances to the nearest edge of the exhaust hood.

AMinimum 4' clearance below or beside any door or window that opens Minimum 1’ clearance below or beside any window that does not open.

BMinimum 1' clearance above any door or window that opens

CMinimum 2' clearance from any adjacent building

DMinimum 7' clearance above any grade when adjacent to public walkways NOTE: Vent may not terminate in covered walkway or breezeway.

EMinimum 2' clearance above any grass, plants, or other combustible materials

FMinimum 3' clearance from any forced air intake of any other appliance

GMinimum 2' clearance below eaves or overhangs

HMinimum 1' clearance horizontally from combustible wall

X

Must be a minimum of 2' above the roof

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Page 10