1 4 Installation (For Qualified Installers Only)

Installation Example: Direct "Through-the-wall" Installation

Horizontal Rain Cap

 

 

 

Type "L" Vent

 

 

 

12” Minimum

 

 

House Shield (used to protect exterior wall from soot discoloration) is HIGHLY RECOMMENDED

Wall Thimble

 

(note 3” clearance

3” Minimum

between vent and

combustibles)

7” Minimum

6” Minimum

Floor Protection

.RTV °F 500Silicone

Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of 500° F. RTV silicone into the gap between sections.

3” Minimum

12”

Floor Protection

17-1/4”

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Page 14
Image 14
Lopi Leyden Pellet Stove manual Installation Example Direct Through-the-wall Installation