Diagnostics and Troubleshooting 3-37

Table 3-16

ADU Diagnostic Messages continued

Message

Description

Recommended Action

Accelerator

At least one line in the cache is no

status: Excessive

longer in use due to excessive ECC

ECC errors

errors detected during use of the

detected in at

memory associated with that cache

least one cache

line.

line. As a result,

 

at least one

 

cache line is no

 

longer in use

 

Replacement of cache should be considered. If cache replacement is not done remaining cache lines should continue to operate properly.

Accelerator

During reset initialization obsolete

Normal operations should continue. The

status: Obsolete

data was found in cache. This was

controller will either write data to the drives or

data detected

due to drives being moved and

discard the data completely.

 

written to by another controller.

 

 

 

 

Accelerator

During reset initialization obsolete

Normal operations should continue.

status: Obsolete

data was found in cache and was

 

data was

discarded (not written to drives).

 

discarded

 

 

 

 

 

Accelerator

During reset initialization obsolete

If newer data was overwritten, you may need to

status: Obsolete

data was found in cache. Obsolete

restore newer data; otherwise, normal

data was flushed

data was written to the drives, but

operations should continue.

(written) to

newer data may have been

 

drives

overwritten.

 

 

 

 

Accelerator

Array Accelerator board has been

Check the Disable Code field. Run Array

status:

permanently disabled. It remains

Configuration Utility (ACU) to reinitialize the

Permanently

disabled until it is reinitialized using

Array Accelerator board.

disabled

the Array Configuration Utility (ACU).

 

 

 

 

Accelerator

Possible data loss detected during

There is no way to determine if dirty or bad data

status: Possible

power-up due to all batteries being

was in the cache and is now lost.

data loss in

below sufficient voltage level and no

 

cache

presence of identification signatures

 

 

on the Array Accelerator board.

 

 

 

 

Accelerator

Array Accelerator board has been

Check the Disable Code field.

status:

temporarily disabled.

 

Temporarily

 

 

disabled

 

 

 

 

 

Accelerator

A status returned from the Array

Obtain the latest version of ADU.

status:

Accelerator board that ADU does not

 

Unrecognized

recognize.

 

status

 

 

 

 

 

Accelerator

Valid data was found in posted write

Not an error or data loss condition; no action

status: Valid data

memory at reinitialization. Data will

required

found at reset

be flushed to disk.

 

 

 

 

Accelerator

Catastrophic problem with Array

Replace the Array Accelerator board.

status: Warranty

Accelerator board. Refer to other

 

alert

messages on Diagnostics screen for

 

 

exact meaning of this message.

 

continued

Page 91
Image 91