Image 67

Diagnostics and Troubleshooting 3-13

Table 3-2

POST Error Messages continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1702 - SCSI cable

None

Termination or cabling problem

error detected;

 

with the system board integrated

system halted.

 

SCSI controller.

Refer to cabling diagrams in Chapter 2 of this guide, the cabling guidelines on the Compaq website, and your Compaq server documentation.

1703 - SCSI cable

None

Incorrect cabling

Ensure that the integrated SCSI

error detected.

 

 

controller has SCSI termination

Internal SCSI cable

 

 

attached.

not attached to

 

 

 

system board

 

 

 

connector. System

 

 

 

halted.

 

 

 

 

 

 

 

1720 - Slot x Drive

None

Prefailure condition

Indicated drive has reported a

Array—SMART hard

 

 

SMART predictive-failure

Drive Detects

 

 

condition and may fail at some

Imminent Failure

 

 

time in the future. If drive is part

SCSI: Port n:

 

 

of a non-fault-tolerant

SCSI ID x

 

 

configuration, back up all data

 

 

 

before replacing drive and

 

 

 

restore all data afterward. If

 

 

 

drive is part of a fault-tolerant

 

 

 

configuration do not replace the

 

 

 

drive unless all other drives in

 

 

 

the array are online. Press F1 to

 

 

 

resume.

 

 

 

 

1721 - Slot x Drive

None

Monitor and performance

Replace the drive when it is

Array—Drive

 

threshold exceeded condition.

reasonable for you to do. The

parameter tracking

 

 

drive has not failed, but Compaq

predicts imminent

 

 

recommends you replace the

failure. The following

 

 

drive.

devices should be

 

 

 

replaced when

 

 

 

conditions permit. Do

 

 

 

not replace drive

 

 

 

unless all other

 

 

 

drives in the array

 

 

 

are online! Back up

 

 

 

data before replacing

 

 

 

drive(s) if using

 

 

 

RAID 0.

 

 

 

 

 

 

 

 

 

 

continued

Page 67